| El monitor Neurosign 100 consta de cuatro componentes: |
|
 |
| Unidad Central |
| |
 |
 |
| Estimulador |
Preamplificador |
|
| 1) Unidad Central: |
| - |
Monitoriza con señal acústica y visual. |
| - |
Estimula con selección de frecuencia e intensidad. |
|
| |
| 2) Estimulador: |
Sonda bipolar que estimula el nervio para observar su respuesta. |
|
| |
| 3) Preamplificador: |
Amplifica los voltajes producidos durante las contracciones musculares. |
|
| |
| 4) Electrodos: |
Conectan el tubo endotraqueal, que pasa por las cuerdas vocales, con el monitor a través del preamplificador. |
|
| |
|
| |
|
| |
|
|
| Catalog Number |
Description |
Weigth |
| 7033-0900 |
110-120V with Power Cord-Stimulator/Monitor Dimensions 290 mm x 260 mm x 100 mm |
12.7 lbs./6 kg. |
|
| |
|
| |
|
|
| Catalog Number |
Description |
| 7033-0902 |
Pre-Amplifier Pod Interface of Electrodes to Control Unit (Clip Attaches to O.R. Table) |
|
| |
|
| |
|
|
Units per Box: 1. |
| Catalog Number |
Description |
Length |
| 7033-0936 |
Disposable Electrode Set, Touchproof Connectors Sterile Package |
12 mm |
| 7033-0937 |
Disposable Channel 1, Touch Proof Connectors Sterile Package |
12 mm |
| 7033-0938 |
Disposable Channel 2, Touch Proof Connectors Sterile Package |
12 mm |
| 7033-0940 |
Disposable Electrode Set, Touchproof Connectors Sterile Package |
20 mm |
| 7033-0941 |
Disposable Channel 1, Touch Proof Connectors Sterile Package |
20 mm |
| 7033-0942 |
Disposable Channel 2, Touch Proof Connectors Sterile Package |
20 mm |
| 7033-0943 |
Disposable Electrode Set, Touchproof Connectors Sterile Package |
25 mm |
| 7033-0944 |
Disposable Channel 1, Touch Proof Connectors Sterile Package |
25 mm |
| 7033-0945 |
Disposable Channel 2, Touch Proof Connectors Sterile Package |
25 mm |
| 7033-0939 |
Disposable Electrode Set, Touchproof Connectors Sterile Package |
- |
| 7033-0903 |
Reusable Channel 1, Touch Proof Connectors Nonsterile Package |
20 mm |
| 7033-0912 |
Reusable Channel 2, Touch Proof Connectors Nonsterile Package |
20 mm |
| 7033-0913 |
Reusable Ground Electrode, Touch Proof Connectors Nonsterile Package |
20 mm |
|
| |
|
| |
|
|
Medical Grade Silicone |
| Catalog Number |
Description |
| 7033-0909 |
Simulator Probe Pod, Interface of Simulation Probes and Instruments to Control Unit |
|
| |
|
| |
|
|
| Catalog Number |
Description |
Sterile Pkg. |
Units per Box |
| 7033-0906 |
Sterile Disposable Monopolar Probe |
Yes |
1 |
| 7033-0919 |
Concentric Bipolar Probe, Touch Proof Conectors |
No |
1 |
| 7033-0920 |
Bipolar Probe Small, Straight, Touch Proof Conectors |
No |
1 |
| 7033-0976 |
Disposable Concentric Bipolar Probe |
Yes |
10 |
| 7033-0977 |
Disposable Bipolar Probe |
Yes |
10 |
| 7033-0978 |
Disposable Monopolar Probe (requires 7033-0979 Ground Electrode) |
Yes |
10 |
| 7033-0979 |
Ground Electrode |
Yes |
20 |
|
| |
|
| |
| |
Impedance Meter, Touch Proof Conecters |
|
|
| Catalog Number |
Description |
Sterile Pkg. |
Units per Box |
| 7033-0954 |
Impedance Meter, Touch Proof Connections |
No |
1 |
|
| |
|
| |
|
|
| Catalog Number |
Description |
Sterile Pkg. |
Units per Box |
| 7033-0935 |
Bipolar Forceps, Bayonet, Touch Proof Adaptor |
No |
1 |
| 7033-0922 |
Bipolar Forceps, Straight |
No |
1 |
|
| |
|
| |
|
|
| Catalog Number |
Description |
Sterile Pkg. |
Units per Box |
| 33-0726 |
Posterior Fossa Neuroelevator |
No |
1 |
| 33-0727 |
Posterior Fossa Neuropick |
No |
1 |
| 33-0728 |
Neuropick |
No |
1 |
| 33-0729 |
Neuroneedle |
No |
1 |
| 33-0730 |
Neuroknife |
No |
1 |
| 33-0731 |
Neuroelevator |
No |
1 |
| 7033-0932 |
Instrument Adaptor Cable |
No |
1 |
|
| |
|
| |
|
Electrodo flexible para monitorizar el nervio laríngeo recurrente durante cirugías de tiroides. Se adhiere al tubo endotraueal y no es invasivo. Existen dos medidas. |
|
| Referencia |
Descripción |
| 1360-00 |
Para tubos de intubación de 6 y 7 mm. |
| 1361-00 |
Para tubos de intubación de 8 y 9 mm. |
|
| |
|
| |