Platinum/Plasti-PoreTM Material. |
Plasti-PoreTM material shaft invites ingrowth for stabilizing the prosthesis in the oval window niche or on a tissue graft. The piston features an Armstrong-style platinum "ribbon" which resists "spring back", permiting proper forceps closure on the incus. Flat cross-section of the loop provides a wide area of contact to discourage point necrosis. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0760 |
0.6 mm |
3.5 mm |
| 14-0761 |
0.6 mm |
3.75 mm |
| 14-0762 |
0.6 mm |
4 mm |
| 14-0763 |
0.6 mm |
4.25 mm |
| 14-0764 |
0.6 mm |
4.5 mm |
| 14-0765 |
0.6 mm |
4.75 mm |
| 14-0766 |
0.6 mm |
5 mm |
| 14-0770 |
0.8 mm |
3.5 mm |
| 14-0771 |
0.8 mm |
3.75 mm |
| 14-0772 |
0.8 mm |
4 mm |
| 14-0773 |
0.8 mm |
4.25 mm |
| 14-0774 |
0.8 mm |
4.5 mm |
| 14-0776 |
0.8 mm |
5 mm |
|
| |
|
| |
|
|
Fluoroplastic |
Loop is expanded with a pick to slip over the incus with smooth jaw alligator forceps. "Plastic memory" provides secure closure. |
|
| Catalog Number |
Piston Diameter |
Loop I.D. |
Functional Length |
| 14-0457 |
0.4 mm |
0.6 mm |
6 mm |
|
As developed in conjunction with Jean-Bernard Causse, M.D., Béziers, France. |
|
| |
|
| |
|
|
Fluoroplastic |
Incus attachment with a very slim 0.30 mm (0.012") diameter shaft. |
|
| Catalog Number |
Piston Diameter |
Loop I.D. |
Functional Length |
| 14-0262 |
0.3 mm |
0.8 mm |
3.5 mm |
| 14-0264 |
0.3 mm |
0.8 mm |
4 mm |
| 14-0265 |
0.3 mm |
0.8 mm |
4.25 mm |
| 14-0266 |
0.3 mm |
0.8 mm |
4.5 mm |
| 14-0268 |
0.3 mm |
0.8 mm |
5 mm |
| 14-0270 |
0.3 mm |
0.8 mm |
5.5 mm |
| 14-0272 |
0.3 mm |
0.8 mm |
6 mm |
|
Designed for Sir Terrence Cawthorne, London, England. |
|
| |
|
| |
|
|
Platinum Ribbon/Fluoroplastic Shaft |
Shortened Fluoroplastic Shaft offers improved visibility during placement. |
|
| Catalog Number |
Piston Diameter |
Piston Length |
| 7014-0730 |
0.6 mm |
3.5 mm |
| 7014-0731 |
0.6 mm |
3.75 mm |
| 7014-0732 |
0.6 mm |
4 mm |
| 7014-0733 |
0.6 mm |
4.25 mm |
| 7014-0734 |
0.6 mm |
4.5 mm |
| 7014-0735 |
0.6 mm |
4.75 mm |
| 7014-0736 |
0.6 mm |
5 mm |
|
Designed for Antonio De La Cruz, M.D., Los Angeles, CA. |
|
| |
|
| |
|
|
Stainless Steel/Fluoroplastic Shaft |
Shortened Fluoroplastic Shaft offers improved visibility during placement. |
|
| Catalog Number |
Piston Diameter |
Piston Length |
| 7014-0726 |
0.6 mm |
3.75 mm |
| 7014-0727 |
0.6 mm |
4 mm |
| 7014-0728 |
0.6 mm |
4.25 mm |
| 7014-0729 |
0.6 mm |
4.5 mm |
| 7014-0737 |
0.6 mm |
4.75 mm |
|
Designed for Antonio De La Cruz, M.D., Los Angeles, CA |
|
| |
|
| |
|
|
Fluoroplastic |
Loop is expanded with a pick to slip over the incus with smooth jaw alligator forceps. "Plastic memory" provides secure closure. |
|
| Catalog Number |
Piston Diameter |
Loop I.D. |
Functional Length |
| 14-0074 |
0.6 mm |
0.6 mm |
3.5 mm |
| 14-0076 |
0.6 mm |
0.6 mm |
4 mm |
| 14-0078 |
0.6 mm |
0.6 mm |
4.5 mm |
| 14-0080 |
0.6 mm |
0.6 mm |
5 mm |
| 14-0082 |
0.6 mm |
0.6 mm |
6 mm |
| 14-0066 |
0.8 mm |
0.6 mm |
4 mm |
| 14-0068 |
0.8 mm |
0.6 mm |
4.5 mm |
| 14-0070 |
0.8 mm |
0.6 mm |
5 mm |
| 14-0072 |
0.8 mm |
0.6 mm |
6 mm |
| 14-0456 |
0.6 mm |
0.8 mm |
6 mm |
|
| |
|
| |
|
|
The unique crfimp in the wire loop coupled with the shepherd crook assists the surgeon in positioning and crimping the prosthesis onto the incus. 0.5 mm hash mark assists in proper seating into stapedotomy. |
|
| Catalog Number |
Description |
Piston Diameter |
Functional Length |
| 7014-5953 |
Fluoroplastic/Platinum |
0.6 mm |
5 mm |
| 7014-5950 |
Fluoroplastic/Platinum |
0.6 mm |
4 mm |
| 7014-5951 |
Fluoroplastic/Platinum |
0.6 mm |
4.25 mm |
| 7014-5952 |
Fluoroplastic/Platinum |
0.6 mm |
4.5 mm |
|
Designed by Charles Mangham, M.D., Seattle, WA.. |
|
| |
|
| |
|
|
Tehe round platinum shaft may be easily angulated. The flat ribbon crook maximizes surface contact with the incus while minimizing the chance of pressure necrosis of the long process. |
|
| Catalog Number |
Description |
Piston Diameter |
Functional Length |
| 7014-0799 |
Fluoroplastic/Platinum |
0.6 mm |
4 mm |
| 7014-0801 |
Fluoroplastic/Platinum |
0.6 mm |
4.25 mm |
| 7014-0798 |
Fluoroplastic/Platinum |
0.6 mm |
4.5 mm |
|
Designed by Michael J. Mckenna & Joseph B. Nadol, Jr., M.D., Boston, Ma. |
|
| |
|
| |
|
|
Platinum/Stainless Steel |
This improved version of the popular McGee Pistons features a platinum ribbon loop attached to a stainless steel piston. Platinum offers good tissue tolerance and is eassier to bend into shape. In its flattened form, it permits a greater area of surface contact with the incus, lessenging the opportunity for pressure necrosis. Each piston also includes a 0.5 mm depth groove to assist in visualization of footplate penetration. This groove is clearly visible at virtually aby angle. A choice of piston diameters is available. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0336 |
0.5 mm |
3.75 mm |
| 14-0337 |
0.5 mm |
4 mm |
| 14-0338 |
0.5 mm |
4.25 mm |
| 14-0339 |
0.5 mm |
4.5 mm |
| 14-0340 |
0.5 mm |
4.75 mm |
| 14-0341 |
0.5 mm |
5 mm |
| 14-0330 |
0.6 mm |
3.75 mm |
| 14-0331 |
0.6 mm |
4 mm |
| 14-0332 |
0.6 mm |
4.25 mm |
| 14-0333 |
0.6 mm |
4.5 mm |
| 14-0334 |
0.6 mm |
4.75 mm |
| 14-0335 |
0.6 mm |
5 mm |
|
Designed for T. Manford McGee, M.D., Detroit, MI. |
|
| |
|
| |
|
|
Stainless Steel |
Use for obliterative ostosclerosis and in cases where the prognosis is poor if the classical fat-wire technique is used. One-piece construction. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0161 |
0.6 mm |
3.25 mm |
| 14-0162 |
0.6 mm |
3.5 mm |
| 14-0163 |
0.6 mm |
3.75 mm |
| 14-0164 |
0.6 mm |
4. mm |
| 14-0165 |
0.6 mm |
4.25 mm |
| 14-0166 |
0.6 mm |
4.5 mm |
| 14-0167 |
0.6 mm |
4.75 mm |
| 14-0168 |
0.6 mm |
5 mm |
| 14-0143 |
0.8 mm |
3.25 mm |
| 14-0144 |
0.8 mm |
3.5 mm |
| 14-0145 |
0.8 mm |
3.75 mm |
| 14-0146 |
0.8 mm |
4. mm |
| 14-0147 |
0.8 mm |
4.25 mm |
| 14-0148 |
0.8 mm |
4.5 mm |
| 14-0149 |
0.8 mm |
4.75 mm |
| 14-0150 |
0.8 mm |
5 mm |
|
Designed for T. Manford McGee, M.D., Detroit, MI. |
|
| |
|
| |
| |
McGee Shepherd´s Crook Pistons |
|
|
Stainless Steel |
Unique hook shape is a easier to install over the incus by offering clearer visualization of closure. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0473 |
0.6 mm |
3.5 mm |
| 14-0475 |
0.6 mm |
4 mm |
| 14-0477 |
0.6 mm |
4.5 mm |
| 14-0479 |
0.6 mm |
5. mm |
| 14-0481 |
0.6 mm |
5.5 mm |
|
Designed by Charles Mangham, M.D., Seattle, WA. |
|
| |
|
| |
| |
Richards Platinum Fluoroplastic Pistons |
|
|
Platinum/Fluoroplastic |
This design incorporates the popular fluoroplastic piston shaft with the Gyrus ENT Platinum Ribbon Loop. Platinum is a wll-tolerated, "obedient" metal that is easy to crimp with virtually no "spring-back". The loop is a flat cross-section (rather than round), providing a wide area of contact to discourage point necrosis and to provide superior purchase. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-1812 |
0.4 mm |
3.5 mm |
| 14-1813 |
0.4 mm |
3.75 mm |
| 14-1814 |
0.4 mm |
4 mm |
| 14-1815 |
0.4 mm |
4.25 mm |
| 14-1816 |
0.4 mm |
4.5 mm |
| 14-1817 |
0.4 mm |
4.75 mm |
| 14-1818 |
0.4 mm |
5 mm |
| 14-0813 |
0.5 mm |
3.75 mm |
| 14-0814 |
0.5 mm |
4 mm |
| 14-0815 |
0.5 mm |
4.25 mm |
| 14-0816 |
0.5 mm |
4.5 mm |
| 14-0817 |
0.5 mm |
4.75 mm |
| 14-0818 |
0.5 mm |
5 mm |
| 14-0781 |
0.6 mm |
3.5 mm |
| 14-0782 |
0.6 mm |
3.75 mm |
| 14-0783 |
0.6 mm |
4 mm |
| 14-0784 |
0.6 mm |
4.25 mm |
| 14-0785 |
0.6 mm |
4.5 mm |
| 14-0786 |
0.6 mm |
4.75 mm |
| 14-0787 |
0.6 mm |
5 mm |
| 14-0790 |
0.8 mm |
3.5 mm |
| 14-0791 |
0.8 mm |
3.75 mm |
| 14-0792 |
0.8 mm |
4 mm |
| 14-0793 |
0.8 mm |
4.25 mm |
| 14-0794 |
0.8 mm |
4.5 mm |
| 14-0795 |
0.8 mm |
4.75 mm |
| 14-0796 |
0.8 mm |
5 mm |
|
| |
|
| |
|
|
Stainless Steel/Fluoroplastic |
For use in incus attachment. Wire loop locks on long process of the incus. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0571 |
0.6 mm |
4.5 mm |
| 14-0573 |
0.6 mm |
5 mm |
|
Designed for Bernard J. Ronis, M.D., Philadelphia, PA. |
|
| |
|
| |
|
|
Fluoroplastic/Platinum |
Trimmable to length. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 7014-0797 |
0.5 mm |
6 mm |
|
Designed Professor Sanna, Piacenza, Italy. |
|
| |
| |
|
| |
|
|
Stainless Steel /Fluoroplastic |
For incus attachment. Wire Loop locks on long process of the incu. A graft may be placed around piston to seal the oval windows. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0120 |
0.6 mm |
3 mm |
| 14-0121 |
0.6 mm |
3.25 mm |
| 14-0122 |
0.6 mm |
3.5 mm |
| 14-0123 |
0.6 mm |
3.75 mm |
| 14-0124 |
0.6 mm |
4 mm |
| 14-0125 |
0.6 mm |
4.25 mm |
| 14-0126 |
0.6 mm |
4.5 mm |
| 14-0127 |
0.6 mm |
4.75 mm |
| 14-0128 |
0.6 mm |
5 mm |
| 14-0129 |
0.6 mm |
5.25 mm |
| 14-0130 |
0.6 mm |
5.5 mm |
| 14-0131 |
0.6 mm |
5.75 mm |
| 14-0102 |
0.8 mm |
3.5 mm |
| 14-0103 |
0.8 mm |
3.75 mm |
| 14-0104 |
0.8 mm |
4 mm |
| 14-0105 |
0.8 mm |
4.25 mm |
| 14-0106 |
0.8 mm |
4.5 mm |
| 14-0107 |
0.8 mm |
4.75 mm |
| 14-0108 |
0.8 mm |
5 mm |
| 14-0110 |
0.8 mm |
5.5 mm |
| 14-0111 |
0.8 mm |
5.75 mm |
|
Designed for Harold F. Schuknecht, M.D., Boston, MA. |
|
| |
|
| |
|
|
Nitinol/Fluoroplastic |
For incus attachment. Piston wire safely & securely fashions itself around the long process when heat is applied, minimizing the potential for under-crimping or over crimping. |
|
| Catalog Number |
Description |
Piston Diameter |
Functional Length |
| 7014-2168 |
Fluoroplastic/Nitinol |
0.4 mm |
3.5 - 5.25 mm Trimmable |
| 7014-5920 |
Fluoroplastic/Nitinol |
0.5 mm |
3.75 mm |
| 7014-5921 |
Fluoroplastic/Nitinol |
0.5 mm |
4 mm |
| 7014-5922 |
Fluoroplastic/Nitinol |
0.5 mm |
4.25 mm |
| 7014-5923 |
Fluoroplastic/Nitinol |
0.5 mm |
4.5 mm |
| 7014-5924 |
Fluoroplastic/Nitinol |
0.5 mm |
4.75 mm |
| 7014-5925 |
Fluoroplastic/Nitinol |
0.6 mm |
3.75 mm |
| 7014-5926 |
Fluoroplastic/Nitinol |
0.6 mm |
4 mm |
| 7014-5927 |
Fluoroplastic/Nitinol |
0.6 mm |
4.25 mm |
| 7014-5928 |
Fluoroplastic/Nitinol |
0.6 mm |
4.5 mm |
| 7014-5929 |
Fluoroplastic/Nitinol |
0.6 mm |
4.75 mm |
| 7014-5930 |
Fluoroplastic/Nitinol |
0.8 mm |
3.75 mm |
| 7014-5931 |
Fluoroplastic/Nitinol |
0.8 mm |
4 mm |
| 7014-5932 |
Fluoroplastic/Nitinol |
0.8 mm |
4.25 mm |
| 7014-5933 |
Fluoroplastic/Nitinol |
0.8 mm |
4.5 mm |
| 7014-5934 |
Fluoroplastic/Nitinol |
0.8 mm |
4.75 mm |
|
| |
|
| |
|
|
Nitinol/Fluoroplastic |
Shortened fluoroplastic shaft offers improved visibility during placement. Nitinol wire securely fashions around the incus when heat is applied. |
|
| Catalog Number |
Description |
Piston Diameter |
Functional Length |
| 7014-2056 |
Nitinol/Fluoroplastic |
0.6 mm |
4 mm |
| 7014-2057 |
Nitinol/Fluoroplastic |
0.6 mm |
4.25 mm |
| 7014-2058 |
Nitinol/Fluoroplastic |
0.6 mm |
4.5 mm |
| 7014-2059 |
Nitinol/Fluoroplastic |
0.6 mm |
4.75 mm |
|
Developed in conjunction with Antonio De La Cruz, Los Angeles, CA. |
|
| |
|
| |
| |
SMart Piston Heating Device |
|
|
| Catalog Number |
Description |
Unit Per Box |
| 7013-1012 |
SMart Thermal Handle with AA Battery |
1 |
| 7013-1013 |
SMart Thermal Tip & Drape |
6 |
|
| |
|
| |
| |
Touma Modified Shepherd´s Crook Pistons |
|
|
|
| Catalog Number |
Description |
Piston Diameter |
Functional Length |
| 7014-5900 |
Stainless Steel, 0.76 mm Glass Beaded Hash Mark |
0.4 mm |
3.75 mm |
| 7014-5901 |
Stainless Steel, 0.76 mm Glass Beaded Hash Mark |
0.4 mm |
4 mm |
| 7014-5902 |
Stainless Steel, 0.76 mm Glass Beaded Hash Mark |
0.4 mm |
4.25 mm |
|
Developed in conjunction with Joseph Touma, M.D., Hunington, WV. |
|
| |
|
| |
|
|
Platinum/Fluoroplastic |
The flattened tab on the loop enables easier grasping and positioning. The fluoroplastic shaft has two different diameters to enhance visualization and reduce the chance of the implant protruding into the vestibule. |
|
| Cat. Number |
Description |
Piston Diameter |
Functional Length |
| 7014-0391 |
Fluoroplastic/Platinum |
Dual Diameter 0.8 to 0.6 mm, Lower Portion Length |
4 mm |
| 7014-0392 |
Fluoroplastic/Platinum |
Dual Diameter 0.8 to 0.6 mm, Lower Portion Length |
4.25 mm |
| 7014-0393 |
Fluoroplastic/Platinum |
Dual Diameter 0.8 to 0.6 mm, Lower Portion Length |
4.5 mm |
| 7014-0394 |
Fluoroplastic/Platinum |
Dual Diameter 0.8 to 0.6 mm, Lower Portion Length |
4.75 mm |
|
Developed in conjunction with George Velegrakis, M.D., Heraklion Crete, Greece. |
|
| |
|
| |
| |
Cause Bucket Handle Prosthesis |
|
|
|
| Catalog Number |
Piston Diameter |
Well Diameter |
Functional Length |
| 7014-2140 |
0.4 mm |
1.32 mm |
5 mm |
|
Designed by Michael J. Mckenna & Joseph B. Nadol, Jr., M.D., Boston, Ma. |
|
| |
| |
|
| |
| |
Classic Stapes Prostheses |
|
|
Titanium |
Equivalent to basic "Robinson" - type design. |
|
| Catalog Number |
Piston Diameter |
Well Diameter |
Functional Length |
| 7014-2141 |
Narrow, 0.4 mm |
Large, 1 mm |
4 mm |
| 7014-2142 |
Narrow, 0.4 mm |
Standard, 0.9 mm |
4 mm |
| 7014-2143 |
Standard, 0.6 mm |
Large, 1 mm |
4 mm |
| 7014-2144 |
Standard, 0.6 mm |
Standard, 0.9 mm |
4 mm |
| 7014-2145 |
Narrow, 0.4 mm |
Large, 1 mm |
4.5 mm |
| 7014-2146 |
Narrow, 0.4 mm |
Standard, 0.9 mm |
4.5 mm |
| 7014-2147 |
Standard, 0.6 mm |
Large, 1 mm |
4.5 mm |
| 7014-2148 |
Standard, 0.6 mm |
Standard, 0.9 mm |
4.25 mm |
| 7014-2149 |
Standard, 0.6 mm |
Standard, 0.9 mm |
4.5 mm |
| 7014-2150 |
Narrow, 0.4 mm |
Large, 1 mm |
5 mm |
| 7014-2151 |
Narrow, 0.4 mm |
Standard, 0.9 mm |
5 mm |
| 7014-2152 |
Standard, 0.6 mm |
Large, 1 mm |
5 mm |
| 7014-2153 |
Standard, 0.6 mm |
Standard, 0.9 mm |
5 mm |
|
Developed in conjunction with George Velegrakis, M.D., Heraklion Crete, Greece. |
|
| |
|
| |
| |
Lippy Modified Stapes Prostheses |
|
|
Titanium |
Designed to be used when the lenticular process of the incus is missing. This modified prosthesis has a portion of the well removed, allowing the enroled long process to enter from the side. |
|
| Catalog Number |
Piston Diameter |
Well Diameter |
Functional Length |
| 7014-2154 |
0.4 mm |
1 mm |
3.65 mm |
| 7014-2155 |
0.4 mm |
1 mm |
4.15 mm |
| 7014-2156 |
0.4 mm |
1 mm |
4.65 mm |
| 7014-2157 |
0.4 mm |
1 mm |
5.15 mm |
|
Designed by Williams N. Lippy, M.D., Warren, OH. |
|
| |
|
| |
| |
Richards Bucket Handle Prostheses |
|
|
Titanium |
A clinically proven piston design in a choice of well-tolerated material - titanium. The opening in the "bucket" of the prosthesis is modified to allow the incus to assume its corrected anatomical position minimizing the danger of pressure necrosis. The bucket handle fits easily over the lenticular process eliminating any need for crimping and the postoperative chances of presure necrosis. The Bucket Handle Prostheses fits either the left or right ear. A hole in the posterior bucket allows for pick insertion to aid in positioning. Two transaxial holes in the distal end of the prosthesis stern allow for tissue ingrowth to aid in the stabilization of the implant. |
|
| Catalog Number |
Piston Diameter |
Well Diameter |
Functional Length |
| 7014-2158 |
0.4 mm |
1 mm |
3.5 mm |
| 7014-2159 |
0.4 mm |
1 mm |
4 mm |
| 7014-2160 |
0.4 mm |
1 mm |
4.25 mm |
| 7014-2161 |
0.4 mm |
1 mm |
4.5 mm |
| 7014-2162 |
0.4 mm |
1 mm |
5 mm |
| 7014-2163 |
0.6 mm |
1 mm |
3.5 mm |
| 7014-2164 |
0.6 mm |
1 mm |
4 mm |
| 7014-2165 |
0.6 mm |
1 mm |
4.25 mm |
| 7014-2166 |
0.6 mm |
1 mm |
4.5 mm |
| 7014-2167 |
0.6 mm |
1 mm |
5 mm |
|
| |
|
| |
|
|
Fluoroplastic |
Reconstructing the sound-conducting of the middle ear with this precisely engineered fluoroplastic piston closely approximates the natural configuration of the ossicular chain with stable implant attachment in both the vertical and horizontal planes. The unique "cupped" head of the Shea Fluoroplastic Cup Piston accepts the lenticular process of the incus, directing the piston shaft downward at the proper angle to the oval window. A special retaining loop behind the "cup" fits easily around the lower end of the incus to maintain the prosthesis securely in place. |
|
| Catalog Number |
Version |
Piston Diameter |
Loop I.D. |
Cup I.D. |
Functional Length |
| 14-0415 |
Left Ear |
0.8 mm |
1.04 mm |
1.12 mm |
4 mm |
| 14-0416 |
Left Ear |
0.8 mm |
1.04 mm |
1.12 mm |
4.5 mm |
| 14-0417 |
Left Ear |
0.8 mm |
1.04 mm |
1.12 mm |
5 mm |
| 14-0418 |
Left Ear |
0.8 mm |
1.04 mm |
1.12 mm |
6 mm |
| 14-0410 |
Left Ear |
0.8 mm |
0.97 mm |
1.02 mm |
4 mm |
| 14-0411 |
Left Ear |
0.8 mm |
0.97 mm |
1.02 mm |
4.5 mm |
| 14-0412 |
Left Ear |
0.8 mm |
0.97 mm |
1.02 mm |
5 mm |
| 14-0413 |
Left Ear |
0.8 mm |
0.97 mm |
1.02 mm |
6 mm |
| 14-0425 |
Right Ear |
0.8 mm |
1.04 mm |
1.12 mm |
4 mm |
| 14-0426 |
Right Ear |
0.8 mm |
1.04 mm |
1.12 mm |
4.5 mm |
| 14-0427 |
Right Ear |
0.8 mm |
1.04 mm |
1.12 mm |
5 mm |
| 14-0428 |
Right Ear |
0.8 mm |
1.04 mm |
1.12 mm |
6 mm |
| 14-0420 |
Right Ear |
0.8 mm |
0.97 mm |
1.02 mm |
4 mm |
| 14-0421 |
Right Ear |
0.8 mm |
0.97 mm |
1.02 mm |
4.5 mm |
| 14-0422 |
Right Ear |
0.8 mm |
0.97 mm |
1.02 mm |
5 mm |
| 14-0423 |
Right Ear |
0.8 mm |
0.97 mm |
1.02 mm |
6 mm |
|
Designed for John J. Shea; M.D., Menphis, TN. |
|
| |
|
| |
| |
Shea Platinum/Fluoroplastic Cup Pistons |
|
|
Platinum/Fluoroplastic |
Reconstructing the sound-conducting mechanism of the middle ear with this precisely-engineered piston closely approximates the natural configuration of the ossicular chain with stable implant attachment in both the vertical and the horizontal planes. The cut-out "cupped" head accepts the lenticular process of the incus, directing the piston shaft downward at the propper angle to the oval window. The platinum arms are preformed to easily slip over the incus, and may be locked in place using only one hand with closing forceps. Fits either left or right ear. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0634 |
0.6 mm |
3.5 mm |
| 14-0635 |
0.6 mm |
3.75 mm |
| 14-0636 |
0.6 mm |
4 mm |
| 14-0637 |
0.6 mm |
4.25 mm |
| 14-0638 |
0.6 mm |
4.5 mm |
| 14-0639 |
0.6 mm |
4.75 mm |
| 14-0640 |
0.6 mm |
5 mm |
| 14-0644 |
0.6 mm |
4 mm |
| 14-0647 |
0.8 mm |
4.75 mm |
| 14-0648 |
0.8 mm |
5 mm |
|
Designed for John J. Shea; M.D., Menphis, TN. |
|
| |
|
| |
|
|
Stainless Steel |
For incus attachment. Length measured overall. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0180 |
0.13 mm |
3 mm |
| 14-0181 |
0.13 mm |
3.25 mm |
| 14-0182 |
0.13 mm |
3.5 mm |
| 14-0183 |
0.13 mm |
3.75 mm |
| 14-0184 |
0.13 mm |
4. mm |
| 14-0185 |
0.13 mm |
4.25 mm |
| 14-0186 |
0.13 mm |
4.5 mm |
| 14-0187 |
0.13 mm |
4.75 mm |
| 14-0188 |
0.13 mm |
5 mm |
| 14-0189 |
0.13 mm |
5.25 mm |
| 14-0190 |
0.13 mm |
5.5 mm |
| 14-0191 |
0.13 mm |
5.75 mm |
| 14-0192 |
0.13 mm |
6 mm |
| 14-0193 |
0.13 mm |
6.25 mm |
| 14-0194 |
0.13 mm |
6.5 mm |
|
Designed for Howard P. House, M.D., Los Angeles, CA. |
|
| |
|
| |
|
|
Platinum |
Platinum is well-tolerated by tissue. It is exceptionally malleable, retaining its formed shape without "spring-back". Flattened band or "ribbon" permits a greater area contact point on the long process of the incus, lessening the possibility of point necrosis. There is also a wider contact point where the "ribbon" touches the incus. |
|
| Catalog Number |
Overall Length |
| 14-0701 |
3.5 mm |
| 14-0702 |
3.75 mm |
| 14-0703 |
4 mm |
| 14-0704 |
4.25 mm |
| 14-0705 |
4.5 mm |
| 14-0706 |
4.75 mm |
| 14-0707 |
5 mm |
| 14-0708 |
5.25 mm |
| 14-0709 |
5.5 mm |
| 14-0710 |
5.75 mm |
|
| |
|
| |
|
|
Tantalum |
A House-type wire loop made of tantalum, accepted for it´s property of being medically inert and its malleability, which permits a secure closing of the loop. |
|
| Catalog Number |
Material |
Wire Diameter |
Overall Length |
| 14-0719 |
Tantalum |
0.13 mm |
3.5 mm |
| 14-0720 |
Tantalum |
0.13 mm |
3.75 mm |
| 14-0721 |
Tantalum |
0.13 mm |
4 mm |
| 14-0722 |
Tantalum |
0.13 mm |
4.25 mm |
| 14-0723 |
Tantalum |
0.13 mm |
4.5 mm |
| 14-0724 |
Tantalum |
0.13 mm |
4.75 mm |
| 14-0725 |
Tantalum |
0.13 mm |
5 mm |
|
| |
|
| |
|
|
Platinum |
Wide, flat base of the "trapeze" at the distal end of the loop provides greater contact area for improved position at the oval window. Flattened band or "ribbon" permits a greater area of contact point on the long process of the incus, lessening the possibility of point necrosis. There is also a wider contact point where the "ribbon" touches the graft. |
|
| Catalog Number |
Overall Length |
| 14-0741 |
4 mm |
| 14-0743 |
4.5 mm |
| 14-0744 |
4.75 mm |
| 14-0745 |
5 mm |
|
Designed for David Austin, M.D., Twin Falls, ID. |
|
| |
|
| |
| |
McGee Malleus Attached Pistons |
|
|
Platinum/Stainless Steel |
Designed to be used in revision cases, or when the lon process of the incus is not suitable for prosthesis attachment. Longer lengths of this popular pistons allow for malleus attachment. |
|
| Catalog Number |
Piston Diameter |
Diameter |
Functional Length |
| 14-0600 |
0.5 mm |
1.22 mm |
4.5 mm |
| 14-0601 |
0.5 mm |
1.22 mm |
4.75 mm |
|
Designed for T. Manford McGee, M.D., Detroit, MI. |
|
| |
|
| |
| |
Schuknect Malleus Attached Pistons |
|
|
Stainless Steel/Fluoroplastic |
Large, open hook for easy attachment, long curved wire for better angulation to oval windows. Available in two piston diameters. |
|
| Catalog Number |
Piston Diameter |
Functional Length |
| 14-0135 |
0.6 mm |
5.5 mm |
| 14-0136 |
0.6 mm |
5.75 mm |
| 14-0132 |
0.6 mm |
6 mm |
| 14-0115 |
0.8 mm |
5.5 mm |
| 14-0116 |
0.8 mm |
5.75 mm |
| 14-0112 |
0.8 mm |
6 mm |
| 14-0113 |
0.8 mm |
6.25 mm |
| 14-0114 |
0.8 mm |
6.5 mm |
|
Designed for Harold F. Schuknecht, M.D., Boston, MA. |
|
| |
|
| |
| |
Richards Bucket Handle Prostheses |
|
|
A clinically proven piston design in a choice of well-tolerated material - fluoroplastic. The opening of the "bucket" of the prosthesis is modified to allow the incus to assume its correct anatomical position minimizing the danger of pressure necrosis. The bucket handle fits easily over the lenticular process eliminating any need for crimping and the postoperative chances of pressure necrosis. The Bucket Handle Prosthesis fits either the left or right ear. A hole in the posterior bucket allows for pick insertion to aid positioning. |
|
| Catalog Number |
Piston Diameter |
Well Diameter |
Functional Length |
| 14-2148 |
0.4 mm |
1 mm |
3.5 mm |
| 14-2150 |
0.4 mm |
1 mm |
4 mm |
| 14-2152 |
0.4 mm |
1 mm |
4.5 mm |
| 14-2154 |
0.4 mm |
1 mm |
5 mm |
| 14-2132 |
0.6 mm |
1 mm |
3.5 mm |
| 14-2134 |
0.6 mm |
1 mm |
4 mm |
| 14-2136 |
0.6 mm |
1 mm |
4.5 mm |
| 14-2138 |
0.6 mm |
1 mm |
5 mm |
|
| |
|
| |
| |
Shea Malleus Attachment Pistons |
|
|
Fluoroplastic |
This fluoroplastic piston has a larger loop I.D. to fit the incus. Opens with a pick for attachment; "plastic memory" provides secure closure. |
|
| Catalog Number |
Piston Diameter |
Loop I.D. |
Functional Length |
| 14-0432 |
0.8 mm |
0.8 mm |
4.5 mm |
| 14-0434 |
0.8 mm |
0.8 mm |
5 mm |
|
Designed for John J. Shea, M.D., Menphis, TN. |
|
| |
|
| |
| |
Sheehy-Type Incus Replacement Struts |
|
|
Stainless Steel |
For malleus attachment using standard graft procedure in oval window. |
|
| Catalog Number |
Wire Diameter |
Overall Length |
| 14-0458 |
0.13 mm |
5 mm |
| 14-0460 |
0.13 mm |
5.5 mm |
| 14-0461 |
0.13 mm |
5.75 mm |
| 14-0462 |
0.13 mm |
6 mm |
| 14-0463 |
0.13 mm |
6.25 mm |
| 14-0464 |
0.13 mm |
6.5 mm |
| 14-0465 |
0.13 mm |
6.75 mm |
|
Designed for James L. Sheehy, M.D., Los Angeles, CA. & W. Hugh Powers, M.D., Los Angeles, CA. |
|
| |
|
| |
|
|
Stainless Steel |
For Stapes revisions. Piston wire securely fashions itself around the malleus, minimizing the potential for over-crimping or under-crimping. |
|
| Catalog Number |
Description |
Piston Diameter |
Functional Length |
| 7014-2037 |
Fluoroplastic/Nitinol |
0.6 mm |
5.5 mm |
| 7014-2038 |
Fluoroplastic/Nitinol |
0.6 mm |
6 mm |
| 7014-2039 |
Fluoroplastic/Nitinol |
0.6 mm |
6.5 mm |
|
| |
|
| |
| |
Applebaum Incudostapedial Join Prostheses |
|
|
Dense Hydroxilapatite |
Restablishes the ossicular chain when the incudostapedial joint is missing. Eliminates the need for a bone chip interposition or removal of the incus. |
| Recommended Surgical Technique*: |
| 1. |
Elevate a tympanomeatal flap and established good exposure of the incudostapedial joint area. Palpate the incus and stapes to ensure their mobility. |
| 2. |
Determine the appropiate size of the implant required by aproximating the size of the defect. The small prosthesis is generally suficient for most defects with the large prosthesis needed for bigger defects. |
| 3. |
Grasp the implant with alligator forceps and slide the through portion under the long process of the incus. Place the "hole" over the head of the stapes. |
| 4. |
Visulize the head of the stapes through the hole that runs through the prosthesis in order to assure proper positioning of the implant. |
| 5. |
The prosthesis is self-supporting if it is positioned properly. Palpate the malleus to verify good motion transmission the prosthesis to the stapes. |
|
|
| Catalog Number |
Description |
Cannulated |
Dimensions |
| |
|
|
A |
B |
C |
| 14-0956 |
Small |
1 mm |
2 mm |
2 mm |
1.2 mm |
| 14-0957 |
Large |
1 mm |
2.5 mm |
2 mm |
1.2 mm |
|
*As suggested by Edward L. Applebaum, M.D., Chicago, IL. |
|
| |
|
| |
| |
Applebaum Incus Replacement System (I.R.S.) |
|
|
Dense Hydroxilapatite. |
The Applebaum Incus Replacement System has been designed to closely resemble a carved homograft/autograft incus interposition implant. The Applebaum I.R.S. is made of dense hydroxylapatite ans is offered in 5 sizes, eliminating any need to trim. The implants are partialy cannulated to fit on the stapes capitulum, and the carved "notch" engages the malleus handle. Size is easily determined using the Applebaum measuring instrument (Cat. # 13-0976). |
|
| Catalog Number |
Length |
Width |
| 14-0970 |
2 mm |
2.5 mm |
| 14-0971 |
2.25 mm |
2.5 mm |
| 14-0972 |
2.5 mm |
2.5 mm |
| 14-0973 |
3 mm |
2.5 mm |
| 14-0974 |
3.5 mm |
2.5 mm |
|
As developed by Edward L. Applebaum, M.D., Chicago, IL. |
|
| |
|
| |
|
|
Hydoxylapatite/Fluoroplastic |
The Spanner Strut represents a modular approach to incus and incus-stapes replacement. The hydroxylapatite head is designed to cradle the malleus handle and is partially cannulated to fit the shaft. The timmable fluoroplastic shaft is designed with a cupped end to be positioned over the stapes capitulum when an incus replacement is necessary. For incus-stapes replacement, the cupped end is trimmed off. The fluoroplastic shaft is trimmed to fit patient anatomy and can be angled with forceps. |
|
| Catalog Number |
Cup I.D. |
Shaft Diameter |
Overall Length |
| 14-0923 |
1.15 mm |
0.8 mm |
10.9 mm |
|
As developed by Bruce Black, M.D., Brisbane, Australia. |
|
| |
|
| |
| |
Goldenberg Incus Prosthesis |
|
|
Hydroxilapatite/Plasti-PoreTM |
Hydroxilapatite head designed with a "hook" to be rotated inferiorly or superiorly along the length of the malleus handle, and includes a centering hole to view the stapes capitulum. Plasti-PoreTM shaft may be trimmed to exact length and notched for the stapedius tendon. |
|
| Catalog Number |
Cannulated |
Head Dimensions |
| 14-0912 |
Fully |
4.2 mm x 2.3 mm |
|
Developed in conjunction with Robert Goldenberg, M.D., Dayton, OH |
|
| |
|
| |
| |
Goldenberg Incus Prosthesis |
|
|
|
| Catalog Number |
Cannulated |
Head Dimensions |
| 7014-5912 |
Fully Cannulated, 1.12 mm; Functional Length 5.9 mm |
Head 4.2 x 2.3 Thickness |
|
Developed in conjunction with Robert Goldenberg, M.D., Dayton, OH |
|
| |
|
| |
| |
Grate Malleus-to-Stapes Strut |
|
|
Plasti-PoreTM |
This prosthesis is designed to meet the needs of ossicular reconstruction. The radiussed upper portion conforms to the stape of the malleus and the hollow post seats firmly on the stapes superstructure. The Malleus-to-Stapes Strut is made of Plasti-PoreTM material, a porous, hight density polyethylene that allows soft tissue ingrowth. |
|
| Catalog Number |
I.D. |
O.D. |
Overall Length |
| 14-0842 |
1.15 mm |
1.78 mm |
4.7 mm |
|
Designed for M.R. Grate, M.D., Tallahassee, FL. |
|
| |
|
| |
|
|
Hydroxilapatite |
The design of this incus prosthesis implants allows stable placement between the malleus and the capitulum of the stapes. The opening in the wide end of the prosthesis easily fits over the capitulum to aid in stabilization. The unique "stair-step" design allows the prosthesis to bridge the gap between the malleus handle and the capitulum of the stapes. The large flat surface of the prosthesis may rest directly against tympanic membrane. The prosthesis can easily be shaped with a diamond burr using irrigation. |
|
| Catalog Number |
Description |
Height |
Width |
Overall Length |
| 14-0865 |
Partially Cannulated, 0.83 mm |
1.5 mm |
1.5 mm |
6 mm |
| 7014-0990 |
Partially Cannulated, 0.83 mm |
1.5 mm |
1.5 mm |
7 mm |
|
Designed by Jan J. Grote, M.D., Leiden, The Netherlands. |
|
| |
|
| |
| |
eKartush Incus Strut Prostheses |
|
|
Hydroxilapatite |
This dense hydroxylapatite strut was designed to bridge the gap between the malleus handle and capitulum of the stapes. Shaft is fully cannulated for improved visualization. |
|
| Catalog Number |
Cannulated |
Shaft |
Overall Length |
| 14-0853 |
1.17 mm, Fully |
Short |
2.75 mm |
| 14-0854 |
1.17 mm, Fully |
Medium |
3.9 mm |
| 14-0855 |
1.17 mm, Fully |
Long |
4.9 mm |
|
As designed by Jack M. Kartush, M.D., EAR Institute, Michigan EAR Institute. |
|
| |
|
| |
| |
Wehrs Incus Prostheses, Double Notch |
|
|
Hydroxilapatite/HAPEXTM |
The Double Notch Incus Prosthesis is designed for use when the anatomic position of the stapedial head in relation to the malleus handle is between 1.2 and 1.2 mm, or between 3 and 4 mm. For the smaller dimension, the secon notch may be removed with a diamond burr using irrigation. |
|
| Catalog Number |
Description |
Dimensions |
| |
|
A |
B |
C |
D |
| 14-0877 |
Short, Hydroxilapatite |
2.1 mm |
0.9 mm |
1.6 mm |
3.5 mm |
| 14-0941 |
Average, Hydroxilapatite |
2.7 mm |
1.5 mm |
1.6 mm |
3.5 mm |
| 14-0878 |
Medium, Hydroxilapatite |
3.3 mm |
2.1 mm |
1.6 mm |
3.5 mm |
| 14-0879 |
Long, Hydroxilapatite |
4.5 mm |
3.3 mm |
1.6 mm |
3.5 mm |
| 7014-5895 |
Fully Cannulated, 1mm HAPEXTMShaft |
4.5 mm |
3.3 mm |
1.6 mm |
3.5 mm |
|
As designed by Roger E. Wehrs, M.D., Tulsa, OK. |
|
| |
|
| |
| |
Wehrs Incus Prostheses, Single Notch |
|
|
Hydroxilapatite/HAPEXTM |
This SIngle Notch Prosthesis is applicable when the "offset" from the head of the stapes to the malleus handle is estimated to be from 2.0 to 3.0 mm. Lesser or grater distances require the use of a Double Notch Prosthesis. |
|
| Catalog Number |
Description |
Dimensions |
| |
|
A |
B |
C |
| 14-0874 |
Short, Hydroxilapatite |
2.1 mm |
0.9 mm |
2.5 mm |
| 14-0940 |
Average, Hydroxilapatite |
2.7 mm |
1.5 mm |
2.5 mm |
| 14-0875 |
Medium, Hydroxilapatite |
3.3 mm |
2.1 mm |
2.5 mm |
| 14-0876 |
Long, Hydroxilapatite |
4.5 mm |
3.3 mm |
2.5 mm |
| 7014-5894 |
HAPEXTMShaft, Fully Cannulated, 1 mm |
4.5 mm |
3.3 mm |
2.5 mm |
|
Designed by Roger E. Wehrs, M.D., Tulsa, OK. |
|
| |
|
| |
| |
Goldenberg Incus-Stapes Prostheses |
|
|
Hydroxilapatite/Plasti-PoreTM |
Hydroxylapatite head designed with "hook" may be rotated inferiorly or superiorly along the length of the malleus handle. Wire reinforced Plasti-Pore TM shaft is easily trimmed to length and provides stability and memory for behind to proper angulation. |
|
| Catalog Number |
Shaft Diameter |
Overall Length |
| 14-0913 |
0.8 mm |
7.9 mm |
|
As developed in conjunction with Robert Goldenberg, M.D., Dayton, OH. |
|
| |
|
| |
| |
Goldenberg Incus-Stapes Prosthesis |
|
|
Hydroxilapatite/HAPEXTM Shaft |
|
| Catalog Number |
Dimensions |
Funtional Length |
| 7014-5913 |
Head 4.2 x 2.3 mm |
8.2 mm |
|
Designed for Robert Goldenberg, M.D., Dayton, OH. |
|
| |
|
| |
| |
Grote Incus-Stapes Prostheses |
|
|
Hydroxilapatite |
This Prosthesis is designed for use in case of a missing and stapes superstructure but a mobile footplate. Each implant is formed of dense hydroxylapatite, a highly biocompatible material with a chemical composicion nearly identical to bone. This material may rest directly against the tympanic membrane with minimal risk of extrusion. |
To Use: Measure the distance from the footplate to the undersurface of the tympanic membrane and the offset between the centirline of the footplate and the handle of the malleus. Use the measurements to trim the prosthesis to the proper dimensions using a diamond burr and irrigation. From a pocket between the handle of the malleus and the tympanic membrane, place the top of the prosthesis in this pocket, and align the shaft into the footplate. |
|
| Catalog Number |
Shaft |
Handle Length |
Overall Length |
| 14-0869 |
0.76 mm |
6 mm |
10 mm |
| 14-0870 |
0.76 mm |
6 mm |
7 mm |
|
As designed by Jan J. Grote, M.D., Leiden, The Netherlands.. |
|
| |
|
| |
| |
Grote Incus-Stapes Prosthesis |
|
|
|
| Cat. Number |
Description |
Dimensions |
| 7014-0991 |
0.91 mm Thick, Handle: 5 mm, Shaft Diameter: 0.76 mm |
10 mm x 5 mm x 9 mm |
|
As designed by Jan J. Grote, M.D., Leiden, The Netherlands. |
|
| |
| |
|
| |
| |
Kartush Incus-Stapes Strut Prostheses |
|
|
Hydroxilapatite |
The dense hydroxylapatite strut was designed to bridge the gap between the malleus handle and stapes footplate. Length may be trimmed using a diamond burr with irrigation. |
|
| Catalog Number |
Description |
Shaft |
Overall Length |
| 14-0850 |
Short |
0.76 mm |
5.3 mm |
| 14-0851 |
Medium |
0.76 mm |
7.3 mm |
| 14-0852 |
Large |
0.76 mm |
10.3 mm |
|
As designed by Jack M. Kartush, M.D., Michigan Ear Institute. |
|
| |
|
| |
| |
Wehrs Incus-Stapes Prostheses, Double Notch |
|
|
Hydroxilapatite/HAPEXTM |
The Double Notch Prosthesis is applicable when the required offset the stapes footplate to the malleus handle is estimated to be between 1.2 and 2.0 mm, or 3.0 and 4.0 mm. The second notch may be removed with a diamond burr and irrigation if not selected for use. |
|
| Catalog Number |
Description |
Dimensions |
| |
|
A |
B |
C |
D |
| 7014-5896 |
0.8 mm HAPEXTM Long Shaft |
10.2 mm |
9 mm |
1.6 mm |
3.5 mm |
|
Designed for Robert Goldenberg, M.D., Dayton, OK. |
|
| |
|
| |
| |
Wehrs Incus-Stapes Prostheses, Single Notch |
|
|
Hydroxilapatite/HAPEXTM |
The Single Notch Prosthesis is designed for use when the required offset from the stapes footplate to the malleus handle is estimated to be from 2 to 3 mm. Other distances require the use of the Double Notch Prosthesis. |
|
| Catalog Number |
Description |
Dimensions |
| |
|
A |
B |
C |
| 7014-5897 |
0.8 mm HAPEXTM Shaft, Long |
10.2 mm |
9 mm |
2.5 mm |
|
Designed for Robert Goldenberg, M.D., Dayton, OK. |
|
| |
| |
|
| |
| |
Wehrs II Incus-Stapes Prostheses, Double Notch |
|
|
Hydroxilapatite |
The Wehrs II features a cut-out in the head of the prostheses which adds increased strength and handling characteristics. |
|
| Catalog Number |
Description |
Dimensions |
| |
|
A |
B |
C |
D |
| 7014-0986 |
0.9 mm, Short |
5.3 mm |
4.1 mm |
1.6 mm |
3.5 mm |
| 7014-0987 |
0.9 mm, Average |
6.3 mm |
5.2 mm |
1.6 mm |
3.5 mm |
| 7014-0988 |
0.9 mm, Medium |
7.3 mm |
6.1 mm |
1.6 mm |
3.5 mm |
| 7014-0989 |
0.9 mm, Large |
10.2 mm |
9.0 mm |
1.6 mm |
3.5 mm |
|
| |
|
| |
| |
Wood Incudostapedial Joint Prosthesis |
|
|
Hydroxilapatite |
The Wehrs II features a cut-out in the head of the prosthesis which adds increased strength and handling characteristics. |
|
| Catalog Number |
Description |
Dimensions |
| |
|
A |
B |
C |
| 7014-0982 |
0.9 mm, Short |
5.3 mm |
4.1 mm |
2.5 mm |
| 7014-0983 |
0.9 mm, Average |
6.3 mm |
5.2 mm |
2.5 mm |
| 7014-0984 |
0.9 mm, Medium |
7.3 mm |
6.1 mm |
2.5 mm |
| 7014-0985 |
0.9 mm, Large |
10.2 mm |
9.0 mm |
2.5 mm |
|
| |
|
| |
| |
Wood Incudostapedial Joint Prosthesis |
|
|
|
| Cat. Number |
Description |
Dimensions |
Functional Length |
| 7014-0958 |
Partially Cannulated, 4 mm Diameter |
4.6 x 3 x 1.5 mm |
4 mm Trimmable |
|
| |
| |
|
| |
| |
Black Oval-Top PORPTM Prostheses |
|
|
Oval top head is made of dense hydrolapatite and designed to minimize extrusion by eliminating any sharp edges. Easily trimmaable Plasti-PoreTM or fluoroplastic shafts are cannlated to acommodate the shapes capitulum. |
|
| Catalog Number |
Material |
Cannulated |
Head Diameter |
Overall Length |
| 14-0859 |
Hydroxylapatite/ Plasti-PoreTM |
Partially, 1.5 mm |
4 x 3 mm |
6.6 mm |
| 14-0857 |
Hydroxylapatite/Fluoroplastic |
Partially, 1.5 mm |
4 x 3 mm |
6.6 mm |
|
As developed in conjunction with Bruce Black, M.D., Brisbane, Australia. |
|
| |
|
| |
| |
Black Oval-Top Universal Prostheses |
|
|
This modular approach to prosthesis design minimizes O.R. inventory by including both a PORPTM and TORPTM shaft which can be assembled in the prosthesis head. Shafts may be trimmed to length as necessary. |
|
| Catalog Number |
Description |
Cannulated |
PORP Type Shaft Diameter |
TORP Type Shaft Diameter |
| 14-0861 |
4 x 3 mm Head |
Hydroxylapatite/ Plasti-PoreTM |
1.15 mm |
0.8 mm (wire) |
| 14-0860 |
4 x 3 mm Head |
Hydroxylapatite/ Fluoroplastic |
1.15 mm |
0.8 mm |
|
Requires O.R. assembly, only one shaft is actually used. |
| U.S. Patent Nos. 4,597,764; D286,909; D286,910. |
As developed in conjuction with Bruce Black, M.D., Brisbane; Australia. |
|
| |
|
| |
|
|
Cartilage attached prosthesis |
|
| Catalog Number |
Material |
Cannulated |
Dimensions |
Functional Length |
| 14-0859 |
Hydroxylapatite Head/ HapexTM Shaft |
Partially, 1.7 mm |
3.5 mm |
9 mm |
|
Developed in conjunction with David C. Kelsall, M.D., Denver, CO. |
|
| |
|
| |
| |
Dornhoffer Malleable PORPTM Prosthesis |
|
|
|
| Catalog Number |
Material |
Cannulated |
Dimensions |
Functional Length |
| 7014-5842 |
Hydroxylapatite Head/ Hapex Shaft |
Partially, 1 mm |
4 x 3.2 mm |
5 mm |
|
Designed for John Dornhoffer, M.D., Little Rock, AR. |
|
| |
|
| |
| |
Dornhoffer Malleable PORPTM Prosthesis |
|
|
|
| Catalog Number |
Material |
Head Diameter |
Functional Length with Cradle |
Overall Length |
| 7014-1014 |
Hydroxylapatite Head/ Titanium Shaft |
3.2 mm |
2.0 mm |
3 mm |
|
Designed for John Dornhoffer, M.D., Little Rock, AR. |
|
| |
|
| |
| |
Drum-to-Stapes Prosthesis PORPTM |
|
|
Plasti-PoreTM |
Hollow post of prosthesis seats firmly on stapes; the thin, broad-faced flange seats against the tympanum with carilage graft. Plasti-PoreTM material construction invites tissue ingrowth to quickly stabilize the prosthesis. Can be to fit, as desired. |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 14-0059 |
Partially, 1.17 mm |
4 mm |
4.75 mm |
|
Designe for Ralph J. Carprosa, M.D., Pitsburg, PA. |
|
| |
|
| |
| |
Drum-to-Stapes Prosthesis PORPTM |
|
|
Plasti-PoreTM |
Hollow post of prosthesis seats firmly on stapes; the thin, broad-faced flange seats against the tympanum with carilage graft. Plasti-PoreTM material construction invites tissue ingrowth to quickly stabilize the prosthesis. Can be to fit, as desired. |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 14-0059 |
Partially, 1.17 mm |
4 mm |
4.75 mm |
|
Designe for Ralph J. Carprosa, M.D., Pitsburg, PA. |
|
| |
|
| |
| |
Goldenberg Cap Prostheses |
|
|
Hydroxilapatite |
Dense hydroxylapatite cap sold separately, to be used in shallow middle ear spaces. |
|
| Catalog Number |
Cannulated |
Overall Length |
| 14-0963 |
Fully |
1.5 mm |
|
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH. |
|
| |
|
| |
| |
Goldenberg Malleable PORPTM Prosthesis |
|
|
Hydroxylapatite/Plasti-PoreTM |
Wedg-shaped, hydroxylapatite head is versatile and may be used if malleus is present but rotated anterioly. Malleable shaft allows proper angulation against the drum and can be easily trimmed to length. |
|
| Catalog Number |
Cannulated |
Overall Length |
| 14-0964 |
Partially |
5.1 mm |
|
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH. |
|
| |
|
| |
| |
Goldenberg Malleable PORPTM Prosthesis |
|
|
Hydroxylapatite Head/HAPEXTM Shaft |
|
| Catalog Number |
Cannulated |
Head Dimensions |
Overall Length |
| 7014-5964 |
Fully, 1.17 mm |
4 x 3mm |
5.6 mm |
|
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH. |
|
| |
|
| |
| |
Goldenberg PORPTM Prosthesis |
|
|
Hydroxylapatite/Plasti-PoreTM |
Wedge-shaped hydroxylapatite head conforms to tympanic membrane and is cannulated to visualize the stapes capitulum. Plasti-Pore shaft is trimmable and can be notched for stapedius tendon. |
|
| Catalog Number |
Cannulated |
Overall Length |
| 14-0916 |
Fully, 1.14 mm |
5.5 mm |
|
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH. |
|
| |
|
| |
| |
Goldenberg PORPTM Prosthesis |
|
|
Hydroxylapatite Head/HAPEXTM Shaft |
|
| Catalog Number |
Cannulated |
Head Dimensions |
Functional Length |
| 7014-5916 |
Fully, 1.17 mm |
4 x 3 mm |
4.75 mm |
|
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH. |
|
| |
|
| |
| |
Haberman PORPTM Prosthesis |
|
|
Hydroxylapatite Head/HAPEXTM Shaft |
Slim design enhances visualization. Notched shaft acommodates stapes cura. Head designed with groove to acommodate malleus. |
|
| Catalog Number |
Description |
Cannulated |
Functional Length |
| 7014-5871 |
Notched for Stapes Cura |
Partially, 1 mm |
2.7 mm |
|
Desgined for Jack Kartush, M.D., Michigan Ear Institute. |
|
| |
|
| |
| |
Modified PORPTM Prosthesis |
|
|
Plasti-PoreTM |
The modified partial ossicular replacement prosthesis (PORPTM) features a cannulation of the prothesis stem which offers the surgeon visibility of the superstructure of the stapes during the entire surgical procedure. Made of Plasti-PoreTM material, a porous high-density polyethylene which is well-tolerates in the body as an implant, the post of the prosthesis seats firmly on the stapes and replaces the malleus and the incus. The implant may be trimmed as desired. |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 14-0084 |
Fully, 1.17 mm |
4 mm |
5 mm |
|
Designed for Leslie J. Block, M.D., Chicago, IL. |
|
| |
|
| |
| |
MicronTM Adjustable Titanium PORPTM Prosthesis |
|
|
Titanium |
The MicronTM Titanium PORPTM features a large open-head design for good visualization. Its adjustable nature allows for minimal stocking levels. |
|
| Catalog Number |
Description |
Dimensions |
| 7014-1046 |
Centered |
2 - 5 mm |
| 7014-1047 |
Off - Centered |
2 - 5 mm |
|
| Catalog Number |
Description (May Be Used with Above Products) |
| 7013-5802 |
Sizing Block |
| 55-0108 |
Ryder Needle Holder (Implant Crimper) |
|
| |
|
| |
| |
MicronTM All Titanium PORPTM |
|
|
Titanium |
The Monolithic PORPsTM come pre-sized so that the surgeon does not need to trim the prosthesis. Additionally, the open-head design allows for good visualization. |
|
| Catalog Number |
Description |
Functional Length |
Cradle Functional Diameter |
Head Diameter |
| 7014-2036 |
Centered, Titable Head |
1.5 mm |
1 mm |
3 mm |
| 7014-2004 |
Centered, Titable Head |
2 mm |
1 mm |
3 mm |
| 7014-2028 |
Centered, Titable Head |
2.5 mm |
1 mm |
3 mm |
| 7014-2005 |
Centered, Titable Head |
3 mm |
1 mm |
3 mm |
| 7014-2029 |
Centered, Titable Head |
3.5 mm |
1 mm |
3 mm |
| 7014-2006 |
Centered, Titable Head |
4 mm |
1 mm |
3 mm |
| 7014-2007 |
Off - Centered, Titable Head |
2 mm |
1 mm |
3 mm |
| 7014-2030 |
Off - Centered, Titable Head |
2.5 mm |
1 mm |
3 mm |
| 7014-2008 |
Off - Centered, Titable Head |
3 mm |
1 mm |
3 mm |
| 7014-2031 |
Off - Centered, Titable Head |
3.5 mm |
1 mm |
3 mm |
| 7014-2009 |
Off - Centered, Titable Head |
4 mm |
1 mm |
3 mm |
|
| |
|
| |
| |
MicronTM Titanium PORPTM With Cradle |
|
|
Titanium/Hapex |
Tiltable titanium head and cradle with trimmable HapexTM shaft. |
|
| Catalog Number |
Description |
Functional Length |
Cradle Functional Diameter |
Head Diameter |
| 7014-2002 |
Centered, Titable Head |
4.8 mm |
5.8 mm |
3 mm |
| 7014-2003 |
Off - Centered, Titable Head |
4.8 mm |
5.8 mm |
3 mm |
|
| |
. |
| |
Off-Centered Cap Prosthesis |
|
|
Hydroxylapatite |
An off-centered version of the Shea Cap Prosthesis, used when anatomy does not permit a direct reconstruction. |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 7014-5840 |
Partially, 1 mm |
3 mm |
1.5 mm |
|
An developed in conjuction with John J. Shea, M.D., Memphis, TN. |
|
| |
|
| |
| |
Off-Centered PORPTM Prosthesis |
|
|
Plasti-Pore |
The Off-Centered Plasti-Pore PORPTM is completely cannulated, allowing the surgeon visibility of the superstructure of the stapes during surgery. The position of the shaft permits a direct, rather than angled, stapes to tympanum placement. The implant is made of Plasti-PoreTM material, a porous, hight-density polyethylene which is well-tolerated in the body. The implant may be trimmed as desired. |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 14-0051 |
Fully, 1.17 mm |
4 mm |
4.57 mm |
|
| |
|
| |
| |
Richards Centered Malleable PORPTM Prosthesis |
|
|
Hydroxylapatite Head/HAPEXTM Shaft |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 7014-5889 |
Partially, 1.17 mm |
3.5 mm |
5.8 mm |
|
| |
|
| |
| |
Richards Centered PORPTM Prosthesis |
|
|
Hydroxylapatite |
Fully Cannulated hydroxylapatite partial ossicular replacement prosthesis. |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 14-0892 |
Fully, 1.17 mm |
4 mm |
5.1 mm |
|
| |
|
| |
| |
Richards Centered PORPTM Prosthesis |
|
|
Hydroxylapatite Head/HAPEXTM Shaft |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 7014-5891 |
Partially, 1.17 mm |
3.5 mm |
5.9 mm |
|
| |
|
| |
| |
Richards Off-Centered Malleable PORPTM Prosthesis |
|
|
Hydroxylapatite Head/HAPEXTM Shaft |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 7014-5892 |
Partially, 1.17 mm |
3.5 mm |
5.8 mm |
|
| As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH. |
| |
|
| |
|
| |
| |
Richards Off-Centered PORPTM Prosthesis |
|
|
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 14-0893 |
Fully, 1.17 mm |
4 mm |
5.1 mm |
|
| |
|
| |
| |
Richards Off-Centered PORPTM Prosthesis |
|
|
Hydroxylapatite Head/HAPEXTM Shaft |
|
| Catalog Number |
Cannulated |
Flange Diameter |
Overall Length |
| 7014-5893 |
Fully, 1.17 mm |
3.5 mm |
5.9 mm |
|
| |
|
| |
| |
Schuring Ossicle Cup System |
|
|
Hydroxylapatite/Fluoroplastic |
Intended as a malleus-incus replacement, the Schuring Ossicle Cup System is designed with two parts, a fluoroplastic shaft and a hydroxylapatite cap. The easily trimmable fluoroplastic shaft is cupped to accommodate the stapes capitulum. The partially cannulated cap accommodates the shaft is designed to rest against the tympanic membrane. Each piece can be ordered separately or as set. |
|
| Catalog Number |
Name |
Description |
| 14-1005 |
Ossile Cup System |
Head, 3.8 mm diameter, cannulated to size of shaft diameter (0.58 mm), one set per pack-age (1 each head and shaft) |
| 14-1000 |
Ossile Cup Prosthesis Only |
Shaft, 6 mm long, 0.6 mm diameter; cup, 1.15 mm inside diameter, fluoroplastic material |
| 14-1003 |
Hydroxilapatite Head Only |
3.8 mm diameter, cannulated for Ossile Cup Prosthesis (0.58 mm) |
|
| As developed in conjunction with Arnold Schuring, M.D., Warren, OH. |
|
| |
|
| |
|
|
Hydroxylapatite |
This versatily prosthesis functions as a short PORPTM-type prosthesis, or can be used in conjunction with other available implants or materials to bridge ossicular defects. |
|
| Catalog Number |
Cannulated |
Base Diameter |
| |