  Armstrong-Style Pistons
Platinum/Plasti-PoreTM Material.
Plasti-PoreTM material shaft invites ingrowth for stabilizing the prosthesis in the oval window niche or on a tissue graft. The piston features an Armstrong-style platinum "ribbon" which resists "spring back", permiting proper forceps closure on the incus. Flat cross-section of the loop provides a wide area of contact to discourage point necrosis.
Catalog Number Piston Diameter Functional Length
14-0760 0.6 mm 3.5 mm
14-0761 0.6 mm 3.75 mm
14-0762 0.6 mm 4 mm
14-0763 0.6 mm 4.25 mm
14-0764 0.6 mm 4.5 mm
14-0765 0.6 mm 4.75 mm
14-0766 0.6 mm 5 mm
14-0770 0.8 mm 3.5 mm
14-0771 0.8 mm 3.75 mm
14-0772 0.8 mm 4 mm
14-0773 0.8 mm 4.25 mm
14-0774 0.8 mm 4.5 mm
14-0776 0.8 mm 5 mm
 
 
  Causse Pistons
Fluoroplastic
Loop is expanded with a pick to slip over the incus with smooth jaw alligator forceps. "Plastic memory" provides secure closure.
Catalog Number Piston Diameter Loop I.D. Functional Length
14-0457 0.4 mm 0.6 mm 6 mm
As developed in conjunction with Jean-Bernard Causse, M.D., Béziers, France.
 
 
  Cawthorne Pistons
Fluoroplastic
Incus attachment with a very slim 0.30 mm (0.012") diameter shaft.
Catalog Number Piston Diameter Loop I.D. Functional Length
14-0262 0.3 mm 0.8 mm 3.5 mm
14-0264 0.3 mm 0.8 mm 4 mm
14-0265 0.3 mm 0.8 mm 4.25 mm
14-0266 0.3 mm 0.8 mm 4.5 mm
14-0268 0.3 mm 0.8 mm 5 mm
14-0270 0.3 mm 0.8 mm 5.5 mm
14-0272 0.3 mm 0.8 mm 6 mm
Designed for Sir Terrence Cawthorne, London, England.
 
 
  De la Cruz Pistons
Platinum Ribbon/Fluoroplastic Shaft
Shortened Fluoroplastic Shaft offers improved visibility during placement.
Catalog Number Piston Diameter Piston Length
7014-0730 0.6 mm 3.5 mm
7014-0731 0.6 mm 3.75 mm
7014-0732 0.6 mm 4 mm
7014-0733 0.6 mm 4.25 mm
7014-0734 0.6 mm 4.5 mm
7014-0735 0.6 mm 4.75 mm
7014-0736 0.6 mm 5 mm
Designed for Antonio De La Cruz, M.D., Los Angeles, CA.
 
 
  De la Cruz Pistons
Stainless Steel/Fluoroplastic Shaft
Shortened Fluoroplastic Shaft offers improved visibility during placement.
Catalog Number Piston Diameter Piston Length
7014-0726 0.6 mm 3.75 mm
7014-0727 0.6 mm 4 mm
7014-0728 0.6 mm 4.25 mm
7014-0729 0.6 mm 4.5 mm
7014-0737 0.6 mm 4.75 mm
Designed for Antonio De La Cruz, M.D., Los Angeles, CA
 
 
  Fluoroplastic Pistons
Fluoroplastic
Loop is expanded with a pick to slip over the incus with smooth jaw alligator forceps. "Plastic memory" provides secure closure.
Catalog Number Piston Diameter Loop I.D. Functional Length
14-0074 0.6 mm 0.6 mm 3.5 mm
14-0076 0.6 mm 0.6 mm 4 mm
14-0078 0.6 mm 0.6 mm 4.5 mm
14-0080 0.6 mm 0.6 mm 5 mm
14-0082 0.6 mm 0.6 mm 6 mm
14-0066 0.8 mm 0.6 mm 4 mm
14-0068 0.8 mm 0.6 mm 4.5 mm
14-0070 0.8 mm 0.6 mm 5 mm
14-0072 0.8 mm 0.6 mm 6 mm
14-0456 0.6 mm 0.8 mm 6 mm
 
 
  Mangham Pistons
The unique crfimp in the wire loop coupled with the shepherd crook assists the surgeon in positioning and crimping the prosthesis onto the incus. 0.5 mm hash mark assists in proper seating into stapedotomy.
Catalog Number Description Piston Diameter Functional Length
7014-5953 Fluoroplastic/Platinum 0.6 mm 5 mm
7014-5950 Fluoroplastic/Platinum 0.6 mm 4 mm
7014-5951 Fluoroplastic/Platinum 0.6 mm 4.25 mm
7014-5952 Fluoroplastic/Platinum 0.6 mm 4.5 mm
Designed by Charles Mangham, M.D., Seattle, WA..
 
 
  Mass Eye & Ear Piston
Tehe round platinum shaft may be easily angulated. The flat ribbon crook maximizes surface contact with the incus while minimizing the chance of pressure necrosis of the long process.
Catalog Number Description Piston Diameter Functional Length
7014-0799 Fluoroplastic/Platinum 0.6 mm 4 mm
7014-0801 Fluoroplastic/Platinum 0.6 mm 4.25 mm
7014-0798 Fluoroplastic/Platinum 0.6 mm 4.5 mm
Designed by Michael J. Mckenna & Joseph B. Nadol, Jr., M.D., Boston, Ma.
 
 
  McGee Pistons
Platinum/Stainless Steel
This improved version of the popular McGee Pistons features a platinum ribbon loop attached to a stainless steel piston. Platinum offers good tissue tolerance and is eassier to bend into shape. In its flattened form, it permits a greater area of surface contact with the incus, lessenging the opportunity for pressure necrosis. Each piston also includes a 0.5 mm depth groove to assist in visualization of footplate penetration. This groove is clearly visible at virtually aby angle. A choice of piston diameters is available.
Catalog Number Piston Diameter Functional Length
14-0336 0.5 mm 3.75 mm
14-0337 0.5 mm 4 mm
14-0338 0.5 mm 4.25 mm
14-0339 0.5 mm 4.5 mm
14-0340 0.5 mm 4.75 mm
14-0341 0.5 mm 5 mm
14-0330 0.6 mm 3.75 mm
14-0331 0.6 mm 4 mm
14-0332 0.6 mm 4.25 mm
14-0333 0.6 mm 4.5 mm
14-0334 0.6 mm 4.75 mm
14-0335 0.6 mm 5 mm
Designed for T. Manford McGee, M.D., Detroit, MI.
 
 
  McGee Pistons
Stainless Steel
Use for obliterative ostosclerosis and in cases where the prognosis is poor if the classical fat-wire technique is used. One-piece construction.
Catalog Number Piston Diameter Functional Length
14-0161 0.6 mm 3.25 mm
14-0162 0.6 mm 3.5 mm
14-0163 0.6 mm 3.75 mm
14-0164 0.6 mm 4. mm
14-0165 0.6 mm 4.25 mm
14-0166 0.6 mm 4.5 mm
14-0167 0.6 mm 4.75 mm
14-0168 0.6 mm 5 mm
14-0143 0.8 mm 3.25 mm
14-0144 0.8 mm 3.5 mm
14-0145 0.8 mm 3.75 mm
14-0146 0.8 mm 4. mm
14-0147 0.8 mm 4.25 mm
14-0148 0.8 mm 4.5 mm
14-0149 0.8 mm 4.75 mm
14-0150 0.8 mm 5 mm
Designed for T. Manford McGee, M.D., Detroit, MI.
 
 
  McGee Shepherd´s Crook Pistons
Stainless Steel
Unique hook shape is a easier to install over the incus by offering clearer visualization of closure.
Catalog Number Piston Diameter Functional Length
14-0473 0.6 mm 3.5 mm
14-0475 0.6 mm 4 mm
14-0477 0.6 mm 4.5 mm
14-0479 0.6 mm 5. mm
14-0481 0.6 mm 5.5 mm
Designed by Charles Mangham, M.D., Seattle, WA.
 
 
  Richards Platinum Fluoroplastic Pistons
Platinum/Fluoroplastic
This design incorporates the popular fluoroplastic piston shaft with the Gyrus ENT Platinum Ribbon Loop. Platinum is a wll-tolerated, "obedient" metal that is easy to crimp with virtually no "spring-back". The loop is a flat cross-section (rather than round), providing a wide area of contact to discourage point necrosis and to provide superior purchase.
Catalog Number Piston Diameter Functional Length
14-1812 0.4 mm 3.5 mm
14-1813 0.4 mm 3.75 mm
14-1814 0.4 mm 4 mm
14-1815 0.4 mm 4.25 mm
14-1816 0.4 mm 4.5 mm
14-1817 0.4 mm 4.75 mm
14-1818 0.4 mm 5 mm
14-0813 0.5 mm 3.75 mm
14-0814 0.5 mm 4 mm
14-0815 0.5 mm 4.25 mm
14-0816 0.5 mm 4.5 mm
14-0817 0.5 mm 4.75 mm
14-0818 0.5 mm 5 mm
14-0781 0.6 mm 3.5 mm
14-0782 0.6 mm 3.75 mm
14-0783 0.6 mm 4 mm
14-0784 0.6 mm 4.25 mm
14-0785 0.6 mm 4.5 mm
14-0786 0.6 mm 4.75 mm
14-0787 0.6 mm 5 mm
14-0790 0.8 mm 3.5 mm
14-0791 0.8 mm 3.75 mm
14-0792 0.8 mm 4 mm
14-0793 0.8 mm 4.25 mm
14-0794 0.8 mm 4.5 mm
14-0795 0.8 mm 4.75 mm
14-0796 0.8 mm 5 mm
 
 
  Ronis Pistons
Stainless Steel/Fluoroplastic
For use in incus attachment. Wire loop locks on long process of the incus.
Catalog Number Piston Diameter Functional Length
14-0571 0.6 mm 4.5 mm
14-0573 0.6 mm 5 mm
Designed for Bernard J. Ronis, M.D., Philadelphia, PA.
 
 
  Sanna Pistons
Fluoroplastic/Platinum
Trimmable to length.
Catalog Number Piston Diameter Functional Length
7014-0797 0.5 mm 6 mm
Designed Professor Sanna, Piacenza, Italy.
 
 
 
  Schuknecht Pistons
Stainless Steel /Fluoroplastic
For incus attachment. Wire Loop locks on long process of the incu. A graft may be placed around piston to seal the oval windows.
Catalog Number Piston Diameter Functional Length
14-0120 0.6 mm 3 mm
14-0121 0.6 mm 3.25 mm
14-0122 0.6 mm 3.5 mm
14-0123 0.6 mm 3.75 mm
14-0124 0.6 mm 4 mm
14-0125 0.6 mm 4.25 mm
14-0126 0.6 mm 4.5 mm
14-0127 0.6 mm 4.75 mm
14-0128 0.6 mm 5 mm
14-0129 0.6 mm 5.25 mm
14-0130 0.6 mm 5.5 mm
14-0131 0.6 mm 5.75 mm
14-0102 0.8 mm 3.5 mm
14-0103 0.8 mm 3.75 mm
14-0104 0.8 mm 4 mm
14-0105 0.8 mm 4.25 mm
14-0106 0.8 mm 4.5 mm
14-0107 0.8 mm 4.75 mm
14-0108 0.8 mm 5 mm
14-0110 0.8 mm 5.5 mm
14-0111 0.8 mm 5.75 mm
Designed for Harold F. Schuknecht, M.D., Boston, MA.
 
 
  SMart Pistons
Nitinol/Fluoroplastic
For incus attachment. Piston wire safely & securely fashions itself around the long process when heat is applied, minimizing the potential for under-crimping or over crimping.
Catalog Number Description Piston Diameter Functional Length
7014-2168 Fluoroplastic/Nitinol 0.4 mm 3.5 - 5.25 mm Trimmable
7014-5920 Fluoroplastic/Nitinol 0.5 mm 3.75 mm
7014-5921 Fluoroplastic/Nitinol 0.5 mm 4 mm
7014-5922 Fluoroplastic/Nitinol 0.5 mm 4.25 mm
7014-5923 Fluoroplastic/Nitinol 0.5 mm 4.5 mm
7014-5924 Fluoroplastic/Nitinol 0.5 mm 4.75 mm
7014-5925 Fluoroplastic/Nitinol 0.6 mm 3.75 mm
7014-5926 Fluoroplastic/Nitinol 0.6 mm 4 mm
7014-5927 Fluoroplastic/Nitinol 0.6 mm 4.25 mm
7014-5928 Fluoroplastic/Nitinol 0.6 mm 4.5 mm
7014-5929 Fluoroplastic/Nitinol 0.6 mm 4.75 mm
7014-5930 Fluoroplastic/Nitinol 0.8 mm 3.75 mm
7014-5931 Fluoroplastic/Nitinol 0.8 mm 4 mm
7014-5932 Fluoroplastic/Nitinol 0.8 mm 4.25 mm
7014-5933 Fluoroplastic/Nitinol 0.8 mm 4.5 mm
7014-5934 Fluoroplastic/Nitinol 0.8 mm 4.75 mm
 
 
  SMart De La Cruz Piston
Nitinol/Fluoroplastic
Shortened fluoroplastic shaft offers improved visibility during placement. Nitinol wire securely fashions around the incus when heat is applied.
Catalog Number Description Piston Diameter Functional Length
7014-2056 Nitinol/Fluoroplastic 0.6 mm 4 mm
7014-2057 Nitinol/Fluoroplastic 0.6 mm 4.25 mm
7014-2058 Nitinol/Fluoroplastic 0.6 mm 4.5 mm
7014-2059 Nitinol/Fluoroplastic 0.6 mm 4.75 mm
Developed in conjunction with Antonio De La Cruz, Los Angeles, CA.
 
 
  SMart Piston Heating Device
Catalog Number Description Unit Per Box
7013-1012

SMart Thermal Handle with AA Battery

1
7013-1013 SMart Thermal Tip & Drape 6
 
 
  Touma Modified Shepherd´s Crook Pistons
Stainless Steel
Catalog Number Description Piston Diameter Functional Length
7014-5900 Stainless Steel, 0.76 mm Glass Beaded Hash Mark 0.4 mm 3.75 mm
7014-5901 Stainless Steel, 0.76 mm Glass Beaded Hash Mark 0.4 mm 4 mm
7014-5902 Stainless Steel, 0.76 mm Glass Beaded Hash Mark 0.4 mm 4.25 mm
Developed in conjunction with Joseph Touma, M.D., Hunington, WV.
 
 
  Velegrakis Pistons
Platinum/Fluoroplastic
The flattened tab on the loop enables easier grasping and positioning. The fluoroplastic shaft has two different diameters to enhance visualization and reduce the chance of the implant protruding into the vestibule.
Cat. Number Description Piston Diameter Functional Length
7014-0391 Fluoroplastic/Platinum Dual Diameter 0.8 to 0.6 mm, Lower Portion Length 4 mm
7014-0392 Fluoroplastic/Platinum Dual Diameter 0.8 to 0.6 mm, Lower Portion Length 4.25 mm
7014-0393 Fluoroplastic/Platinum Dual Diameter 0.8 to 0.6 mm, Lower Portion Length 4.5 mm
7014-0394 Fluoroplastic/Platinum Dual Diameter 0.8 to 0.6 mm, Lower Portion Length 4.75 mm
Developed in conjunction with George Velegrakis, M.D., Heraklion Crete, Greece.
 
 
  Cause Bucket Handle Prosthesis
Fluoroplastic
Catalog Number Piston Diameter Well Diameter Functional Length
7014-2140 0.4 mm 1.32 mm 5 mm
Designed by Michael J. Mckenna & Joseph B. Nadol, Jr., M.D., Boston, Ma.
 
 
 
  Classic Stapes Prostheses
Titanium
Equivalent to basic "Robinson" - type design.
Catalog Number Piston Diameter Well Diameter Functional Length
7014-2141 Narrow, 0.4 mm Large, 1 mm 4 mm
7014-2142 Narrow, 0.4 mm Standard, 0.9 mm 4 mm
7014-2143 Standard, 0.6 mm Large, 1 mm 4 mm
7014-2144 Standard, 0.6 mm Standard, 0.9 mm 4 mm
7014-2145 Narrow, 0.4 mm Large, 1 mm 4.5 mm
7014-2146 Narrow, 0.4 mm Standard, 0.9 mm 4.5 mm
7014-2147 Standard, 0.6 mm Large, 1 mm 4.5 mm
7014-2148 Standard, 0.6 mm Standard, 0.9 mm 4.25 mm
7014-2149 Standard, 0.6 mm Standard, 0.9 mm 4.5 mm
7014-2150 Narrow, 0.4 mm Large, 1 mm 5 mm
7014-2151 Narrow, 0.4 mm Standard, 0.9 mm 5 mm
7014-2152 Standard, 0.6 mm Large, 1 mm 5 mm
7014-2153 Standard, 0.6 mm Standard, 0.9 mm 5 mm
Developed in conjunction with George Velegrakis, M.D., Heraklion Crete, Greece.
 
 
  Lippy Modified Stapes Prostheses
Titanium
Designed to be used when the lenticular process of the incus is missing. This modified prosthesis has a portion of the well removed, allowing the enroled long process to enter from the side.
Catalog Number Piston Diameter Well Diameter Functional Length
7014-2154 0.4 mm 1 mm 3.65 mm
7014-2155 0.4 mm 1 mm 4.15 mm
7014-2156 0.4 mm 1 mm 4.65 mm
7014-2157 0.4 mm 1 mm 5.15 mm
Designed by Williams N. Lippy, M.D., Warren, OH.
 
 
  Richards Bucket Handle Prostheses
Titanium
A clinically proven piston design in a choice of well-tolerated material - titanium. The opening in the "bucket" of the prosthesis is modified to allow the incus to assume its corrected anatomical position minimizing the danger of pressure necrosis. The bucket handle fits easily over the lenticular process eliminating any need for crimping and the postoperative chances of presure necrosis. The Bucket Handle Prostheses fits either the left or right ear. A hole in the posterior bucket allows for pick insertion to aid in positioning. Two transaxial holes in the distal end of the prosthesis stern allow for tissue ingrowth to aid in the stabilization of the implant.
Catalog Number Piston Diameter Well Diameter Functional Length
7014-2158 0.4 mm 1 mm 3.5 mm
7014-2159 0.4 mm 1 mm 4 mm
7014-2160 0.4 mm 1 mm 4.25 mm
7014-2161 0.4 mm 1 mm 4.5 mm
7014-2162 0.4 mm 1 mm 5 mm
7014-2163 0.6 mm 1 mm 3.5 mm
7014-2164 0.6 mm 1 mm 4 mm
7014-2165 0.6 mm 1 mm 4.25 mm
7014-2166 0.6 mm 1 mm 4.5 mm
7014-2167 0.6 mm 1 mm 5 mm
 
 
  Shea Cup Pistons
Fluoroplastic
Reconstructing the sound-conducting of the middle ear with this precisely engineered fluoroplastic piston closely approximates the natural configuration of the ossicular chain with stable implant attachment in both the vertical and horizontal planes. The unique "cupped" head of the Shea Fluoroplastic Cup Piston accepts the lenticular process of the incus, directing the piston shaft downward at the proper angle to the oval window. A special retaining loop behind the "cup" fits easily around the lower end of the incus to maintain the prosthesis securely in place.
Catalog Number Version Piston Diameter Loop I.D. Cup I.D. Functional Length
14-0415 Left Ear 0.8 mm 1.04 mm 1.12 mm 4 mm
14-0416 Left Ear 0.8 mm 1.04 mm 1.12 mm 4.5 mm
14-0417 Left Ear 0.8 mm 1.04 mm 1.12 mm 5 mm
14-0418 Left Ear 0.8 mm 1.04 mm 1.12 mm 6 mm
14-0410 Left Ear 0.8 mm 0.97 mm 1.02 mm 4 mm
14-0411 Left Ear 0.8 mm 0.97 mm 1.02 mm 4.5 mm
14-0412 Left Ear 0.8 mm 0.97 mm 1.02 mm 5 mm
14-0413 Left Ear 0.8 mm 0.97 mm 1.02 mm 6 mm
14-0425 Right Ear 0.8 mm 1.04 mm 1.12 mm 4 mm
14-0426 Right Ear 0.8 mm 1.04 mm 1.12 mm 4.5 mm
14-0427 Right Ear 0.8 mm 1.04 mm 1.12 mm 5 mm
14-0428 Right Ear 0.8 mm 1.04 mm 1.12 mm 6 mm
14-0420 Right Ear 0.8 mm 0.97 mm 1.02 mm 4 mm
14-0421 Right Ear 0.8 mm 0.97 mm 1.02 mm 4.5 mm
14-0422 Right Ear 0.8 mm 0.97 mm 1.02 mm 5 mm
14-0423 Right Ear 0.8 mm 0.97 mm 1.02 mm 6 mm
Designed for John J. Shea; M.D., Menphis, TN.
 
 
  Shea Platinum/Fluoroplastic Cup Pistons
Platinum/Fluoroplastic
Reconstructing the sound-conducting mechanism of the middle ear with this precisely-engineered piston closely approximates the natural configuration of the ossicular chain with stable implant attachment in both the vertical and the horizontal planes. The cut-out "cupped" head accepts the lenticular process of the incus, directing the piston shaft downward at the propper angle to the oval window. The platinum arms are preformed to easily slip over the incus, and may be locked in place using only one hand with closing forceps. Fits either left or right ear.
Catalog Number Piston Diameter Functional Length
14-0634 0.6 mm 3.5 mm
14-0635 0.6 mm 3.75 mm
14-0636 0.6 mm 4 mm
14-0637 0.6 mm 4.25 mm
14-0638 0.6 mm 4.5 mm
14-0639 0.6 mm 4.75 mm
14-0640 0.6 mm 5 mm
14-0644 0.6 mm 4 mm
14-0647 0.8 mm 4.75 mm
14-0648 0.8 mm 5 mm
Designed for John J. Shea; M.D., Menphis, TN.
 
 
  House-Types Wire Loops
Stainless Steel
For incus attachment. Length measured overall.
Catalog Number Piston Diameter Functional Length
14-0180 0.13 mm 3 mm
14-0181 0.13 mm 3.25 mm
14-0182 0.13 mm 3.5 mm
14-0183 0.13 mm 3.75 mm
14-0184 0.13 mm 4. mm
14-0185 0.13 mm 4.25 mm
14-0186 0.13 mm 4.5 mm
14-0187 0.13 mm 4.75 mm
14-0188 0.13 mm 5 mm
14-0189 0.13 mm 5.25 mm
14-0190 0.13 mm 5.5 mm
14-0191 0.13 mm 5.75 mm
14-0192 0.13 mm 6 mm
14-0193 0.13 mm 6.25 mm
14-0194 0.13 mm 6.5 mm
Designed for Howard P. House, M.D., Los Angeles, CA.
 
 
  Platinum Ribbons Loops
Platinum
Platinum is well-tolerated by tissue. It is exceptionally malleable, retaining its formed shape without "spring-back". Flattened band or "ribbon" permits a greater area contact point on the long process of the incus, lessening the possibility of point necrosis. There is also a wider contact point where the "ribbon" touches the incus.
Catalog Number Overall Length
14-0701 3.5 mm
14-0702 3.75 mm
14-0703 4 mm
14-0704 4.25 mm
14-0705 4.5 mm
14-0706 4.75 mm
14-0707 5 mm
14-0708 5.25 mm
14-0709 5.5 mm
14-0710 5.75 mm
 
 
  Tantalum Wire Loops
Tantalum
A House-type wire loop made of tantalum, accepted for it´s property of being medically inert and its malleability, which permits a secure closing of the loop.
Catalog Number Material Wire Diameter Overall Length
14-0719 Tantalum 0.13 mm 3.5 mm
14-0720 Tantalum 0.13 mm 3.75 mm
14-0721 Tantalum 0.13 mm 4 mm
14-0722 Tantalum 0.13 mm 4.25 mm
14-0723 Tantalum 0.13 mm 4.5 mm
14-0724 Tantalum 0.13 mm 4.75 mm
14-0725 Tantalum 0.13 mm 5 mm
 
 
  Trapeze Ribbon Loops
Platinum
Wide, flat base of the "trapeze" at the distal end of the loop provides greater contact area for improved position at the oval window. Flattened band or "ribbon" permits a greater area of contact point on the long process of the incus, lessening the possibility of point necrosis. There is also a wider contact point where the "ribbon" touches the graft.
Catalog Number Overall Length
14-0741 4 mm
14-0743 4.5 mm
14-0744 4.75 mm
14-0745 5 mm
Designed for David Austin, M.D., Twin Falls, ID.
 
 
  McGee Malleus Attached Pistons
Platinum/Stainless Steel
Designed to be used in revision cases, or when the lon process of the incus is not suitable for prosthesis attachment. Longer lengths of this popular pistons allow for malleus attachment.
Catalog Number Piston Diameter Diameter Functional Length
14-0600 0.5 mm 1.22 mm 4.5 mm
14-0601 0.5 mm 1.22 mm 4.75 mm
Designed for T. Manford McGee, M.D., Detroit, MI.
 
 
  Schuknect Malleus Attached Pistons
Stainless Steel/Fluoroplastic
Large, open hook for easy attachment, long curved wire for better angulation to oval windows. Available in two piston diameters.
Catalog Number Piston Diameter Functional Length
14-0135 0.6 mm 5.5 mm
14-0136 0.6 mm 5.75 mm
14-0132 0.6 mm 6 mm
14-0115 0.8 mm 5.5 mm
14-0116 0.8 mm 5.75 mm
14-0112 0.8 mm 6 mm
14-0113 0.8 mm 6.25 mm
14-0114 0.8 mm 6.5 mm
Designed for Harold F. Schuknecht, M.D., Boston, MA.
 
 
  Richards Bucket Handle Prostheses
A clinically proven piston design in a choice of well-tolerated material - fluoroplastic. The opening of the "bucket" of the prosthesis is modified to allow the incus to assume its correct anatomical position minimizing the danger of pressure necrosis. The bucket handle fits easily over the lenticular process eliminating any need for crimping and the postoperative chances of pressure necrosis. The Bucket Handle Prosthesis fits either the left or right ear. A hole in the posterior bucket allows for pick insertion to aid positioning.
Catalog Number Piston Diameter Well Diameter Functional Length
14-2148 0.4 mm 1 mm 3.5 mm
14-2150 0.4 mm 1 mm 4 mm
14-2152 0.4 mm 1 mm 4.5 mm
14-2154 0.4 mm 1 mm 5 mm
14-2132 0.6 mm 1 mm 3.5 mm
14-2134 0.6 mm 1 mm 4 mm
14-2136 0.6 mm 1 mm 4.5 mm
14-2138 0.6 mm 1 mm 5 mm
 
 
  Shea Malleus Attachment Pistons
Fluoroplastic
This fluoroplastic piston has a larger loop I.D. to fit the incus. Opens with a pick for attachment; "plastic memory" provides secure closure.
Catalog Number Piston Diameter Loop I.D. Functional Length
14-0432 0.8 mm 0.8 mm 4.5 mm
14-0434 0.8 mm 0.8 mm 5 mm
Designed for John J. Shea, M.D., Menphis, TN.
 
 
  Sheehy-Type Incus Replacement Struts
Stainless Steel
For malleus attachment using standard graft procedure in oval window.
Catalog Number Wire Diameter Overall Length
14-0458 0.13 mm 5 mm
14-0460 0.13 mm 5.5 mm
14-0461 0.13 mm 5.75 mm
14-0462 0.13 mm 6 mm
14-0463 0.13 mm 6.25 mm
14-0464 0.13 mm 6.5 mm
14-0465 0.13 mm 6.75 mm
Designed for James L. Sheehy, M.D., Los Angeles, CA. & W. Hugh Powers, M.D., Los Angeles, CA.
 
 
  SMart Malleus
Stainless Steel
For Stapes revisions. Piston wire securely fashions itself around the malleus, minimizing the potential for over-crimping or under-crimping.
Catalog Number Description Piston Diameter Functional Length
7014-2037 Fluoroplastic/Nitinol 0.6 mm 5.5 mm
7014-2038 Fluoroplastic/Nitinol 0.6 mm 6 mm
7014-2039 Fluoroplastic/Nitinol 0.6 mm 6.5 mm
 
 
  Applebaum Incudostapedial Join Prostheses
Dense Hydroxilapatite
Restablishes the ossicular chain when the incudostapedial joint is missing. Eliminates the need for a bone chip interposition or removal of the incus.
Recommended Surgical Technique*:
1.
Elevate a tympanomeatal flap and established good exposure of the incudostapedial joint area. Palpate the incus and stapes to ensure their mobility.
2. Determine the appropiate size of the implant required by aproximating the size of the defect. The small prosthesis is generally suficient for most defects with the large prosthesis needed for bigger defects.
3.
Grasp the implant with alligator forceps and slide the through portion under the long process of the incus. Place the "hole" over the head of the stapes.
4.
Visulize the head of the stapes through the hole that runs through the prosthesis in order to assure proper positioning of the implant.
5.
The prosthesis is self-supporting if it is positioned properly. Palpate the malleus to verify good motion transmission the prosthesis to the stapes.
Catalog Number Description Cannulated Dimensions
      A B C
14-0956 Small 1 mm 2 mm 2 mm 1.2 mm
14-0957 Large 1 mm 2.5 mm 2 mm 1.2 mm
*As suggested by Edward L. Applebaum, M.D., Chicago, IL.
 
 
  Applebaum Incus Replacement System (I.R.S.)
Dense Hydroxilapatite.
The Applebaum Incus Replacement System has been designed to closely resemble a carved homograft/autograft incus interposition implant. The Applebaum I.R.S. is made of dense hydroxylapatite ans is offered in 5 sizes, eliminating any need to trim. The implants are partialy cannulated to fit on the stapes capitulum, and the carved "notch" engages the malleus handle. Size is easily determined using the Applebaum measuring instrument (Cat. # 13-0976).
Catalog Number Length Width
14-0970 2 mm 2.5 mm
14-0971 2.25 mm 2.5 mm
14-0972 2.5 mm 2.5 mm
14-0973 3 mm 2.5 mm
14-0974 3.5 mm 2.5 mm
As developed by Edward L. Applebaum, M.D., Chicago, IL.
 
 
  SMart Malleus
Hydoxylapatite/Fluoroplastic
The Spanner Strut represents a modular approach to incus and incus-stapes replacement. The hydroxylapatite head is designed to cradle the malleus handle and is partially cannulated to fit the shaft. The timmable fluoroplastic shaft is designed with a cupped end to be positioned over the stapes capitulum when an incus replacement is necessary. For incus-stapes replacement, the cupped end is trimmed off. The fluoroplastic shaft is trimmed to fit patient anatomy and can be angled with forceps.
Catalog Number Cup I.D. Shaft Diameter Overall Length
14-0923 1.15 mm 0.8 mm 10.9 mm
As developed by Bruce Black, M.D., Brisbane, Australia.
 
 
  Goldenberg Incus Prosthesis
Hydroxilapatite/Plasti-PoreTM
Hydroxilapatite head designed with a "hook" to be rotated inferiorly or superiorly along the length of the malleus handle, and includes a centering hole to view the stapes capitulum. Plasti-PoreTM shaft may be trimmed to exact length and notched for the stapedius tendon.
Catalog Number Cannulated Head Dimensions
14-0912 Fully 4.2 mm x 2.3 mm
Developed in conjunction with Robert Goldenberg, M.D., Dayton, OH
 
 
  Goldenberg Incus Prosthesis
Hydroxilapatite/HAPEXTM
Catalog Number Cannulated Head Dimensions
7014-5912 Fully Cannulated, 1.12 mm; Functional Length 5.9 mm Head 4.2 x 2.3 Thickness
Developed in conjunction with Robert Goldenberg, M.D., Dayton, OH
 
 
  Grate Malleus-to-Stapes Strut
Plasti-PoreTM
This prosthesis is designed to meet the needs of ossicular reconstruction. The radiussed upper portion conforms to the stape of the malleus and the hollow post seats firmly on the stapes superstructure. The Malleus-to-Stapes Strut is made of Plasti-PoreTM material, a porous, hight density polyethylene that allows soft tissue ingrowth.
Catalog Number I.D. O.D. Overall Length
14-0842 1.15 mm 1.78 mm 4.7 mm
Designed for M.R. Grate, M.D., Tallahassee, FL.
 
 
  Mass Eye & Ear Piston
Hydroxilapatite
The design of this incus prosthesis implants allows stable placement between the malleus and the capitulum of the stapes. The opening in the wide end of the prosthesis easily fits over the capitulum to aid in stabilization. The unique "stair-step" design allows the prosthesis to bridge the gap between the malleus handle and the capitulum of the stapes. The large flat surface of the prosthesis may rest directly against tympanic membrane. The prosthesis can easily be shaped with a diamond burr using irrigation.
Catalog Number Description Height Width Overall Length
14-0865 Partially Cannulated, 0.83 mm 1.5 mm 1.5 mm 6 mm
7014-0990 Partially Cannulated, 0.83 mm 1.5 mm 1.5 mm 7 mm
Designed by Jan J. Grote, M.D., Leiden, The Netherlands.
 
 
  eKartush Incus Strut Prostheses
Hydroxilapatite
This dense hydroxylapatite strut was designed to bridge the gap between the malleus handle and capitulum of the stapes. Shaft is fully cannulated for improved visualization.
Catalog Number Cannulated Shaft Overall Length
14-0853 1.17 mm, Fully Short 2.75 mm
14-0854 1.17 mm, Fully Medium 3.9 mm
14-0855 1.17 mm, Fully Long 4.9 mm
As designed by Jack M. Kartush, M.D., EAR Institute, Michigan EAR Institute.
 
 
  Wehrs Incus Prostheses, Double Notch
Hydroxilapatite/HAPEXTM
The Double Notch Incus Prosthesis is designed for use when the anatomic position of the stapedial head in relation to the malleus handle is between 1.2 and 1.2 mm, or between 3 and 4 mm. For the smaller dimension, the secon notch may be removed with a diamond burr using irrigation.
Catalog Number Description Dimensions
    A B C D
14-0877 Short, Hydroxilapatite 2.1 mm 0.9 mm 1.6 mm 3.5 mm
14-0941 Average, Hydroxilapatite 2.7 mm 1.5 mm 1.6 mm 3.5 mm
14-0878 Medium, Hydroxilapatite 3.3 mm 2.1 mm 1.6 mm 3.5 mm
14-0879 Long, Hydroxilapatite 4.5 mm 3.3 mm 1.6 mm 3.5 mm
7014-5895 Fully Cannulated, 1mm HAPEXTMShaft 4.5 mm 3.3 mm 1.6 mm 3.5 mm
As designed by Roger E. Wehrs, M.D., Tulsa, OK.
 
 
  Wehrs Incus Prostheses, Single Notch
Hydroxilapatite/HAPEXTM
This SIngle Notch Prosthesis is applicable when the "offset" from the head of the stapes to the malleus handle is estimated to be from 2.0 to 3.0 mm. Lesser or grater distances require the use of a Double Notch Prosthesis.
Catalog Number Description Dimensions
    A B C
14-0874 Short, Hydroxilapatite 2.1 mm 0.9 mm 2.5 mm
14-0940 Average, Hydroxilapatite 2.7 mm 1.5 mm 2.5 mm
14-0875 Medium, Hydroxilapatite 3.3 mm 2.1 mm 2.5 mm
14-0876 Long, Hydroxilapatite 4.5 mm 3.3 mm 2.5 mm
7014-5894 HAPEXTMShaft, Fully Cannulated, 1 mm 4.5 mm 3.3 mm 2.5 mm
Designed by Roger E. Wehrs, M.D., Tulsa, OK.
 
 
  Goldenberg Incus-Stapes Prostheses
Hydroxilapatite/Plasti-PoreTM
Hydroxylapatite head designed with "hook" may be rotated inferiorly or superiorly along the length of the malleus handle. Wire reinforced Plasti-Pore TM shaft is easily trimmed to length and provides stability and memory for behind to proper angulation.
Catalog Number Shaft Diameter Overall Length
14-0913 0.8 mm 7.9 mm
As developed in conjunction with Robert Goldenberg, M.D., Dayton, OH.
 
 
  Goldenberg Incus-Stapes Prosthesis
Hydroxilapatite/HAPEXTM Shaft
Catalog Number Dimensions Funtional Length
7014-5913 Head 4.2 x 2.3 mm 8.2 mm
Designed for Robert Goldenberg, M.D., Dayton, OH.
 
 
  Grote Incus-Stapes Prostheses
Hydroxilapatite
This Prosthesis is designed for use in case of a missing and stapes superstructure but a mobile footplate. Each implant is formed of dense hydroxylapatite, a highly biocompatible material with a chemical composicion nearly identical to bone. This material may rest directly against the tympanic membrane with minimal risk of extrusion.
To Use: Measure the distance from the footplate to the undersurface of the tympanic membrane and the offset between the centirline of the footplate and the handle of the malleus. Use the measurements to trim the prosthesis to the proper dimensions using a diamond burr and irrigation. From a pocket between the handle of the malleus and the tympanic membrane, place the top of the prosthesis in this pocket, and align the shaft into the footplate.
Catalog Number Shaft Handle Length Overall Length
14-0869 0.76 mm 6 mm 10 mm
14-0870 0.76 mm 6 mm 7 mm
As designed by Jan J. Grote, M.D., Leiden, The Netherlands..
 
 
  Grote Incus-Stapes Prosthesis
Dense Hydroxilapatite
Cat. Number Description Dimensions
7014-0991 0.91 mm Thick, Handle: 5 mm, Shaft Diameter: 0.76 mm 10 mm x 5 mm x 9 mm
As designed by Jan J. Grote, M.D., Leiden, The Netherlands.
 
 
 
  Kartush Incus-Stapes Strut Prostheses
Hydroxilapatite
The dense hydroxylapatite strut was designed to bridge the gap between the malleus handle and stapes footplate. Length may be trimmed using a diamond burr with irrigation.
Catalog Number Description Shaft Overall Length
14-0850 Short 0.76 mm 5.3 mm
14-0851 Medium 0.76 mm 7.3 mm
14-0852 Large 0.76 mm 10.3 mm
As designed by Jack M. Kartush, M.D., Michigan Ear Institute.
 
 
  Wehrs Incus-Stapes Prostheses, Double Notch
Hydroxilapatite/HAPEXTM
The Double Notch Prosthesis is applicable when the required offset the stapes footplate to the malleus handle is estimated to be between 1.2 and 2.0 mm, or 3.0 and 4.0 mm. The second notch may be removed with a diamond burr and irrigation if not selected for use.
Catalog Number Description Dimensions
    A B C D
7014-5896 0.8 mm HAPEXTM Long Shaft 10.2 mm 9 mm 1.6 mm 3.5 mm
Designed for Robert Goldenberg, M.D., Dayton, OK.
 
 
  Wehrs Incus-Stapes Prostheses, Single Notch
Hydroxilapatite/HAPEXTM
The Single Notch Prosthesis is designed for use when the required offset from the stapes footplate to the malleus handle is estimated to be from 2 to 3 mm. Other distances require the use of the Double Notch Prosthesis.
Catalog Number Description Dimensions
    A B C
7014-5897 0.8 mm HAPEXTM Shaft, Long 10.2 mm 9 mm 2.5 mm
Designed for Robert Goldenberg, M.D., Dayton, OK.
 
 
 
  Wehrs II Incus-Stapes Prostheses, Double Notch
Hydroxilapatite
The Wehrs II features a cut-out in the head of the prostheses which adds increased strength and handling characteristics.
Catalog Number Description Dimensions
    A B C D
7014-0986 0.9 mm, Short 5.3 mm 4.1 mm 1.6 mm 3.5 mm
7014-0987 0.9 mm, Average 6.3 mm 5.2 mm 1.6 mm 3.5 mm
7014-0988 0.9 mm, Medium 7.3 mm 6.1 mm 1.6 mm 3.5 mm
7014-0989 0.9 mm, Large 10.2 mm 9.0 mm 1.6 mm 3.5 mm
 
 
  Wood Incudostapedial Joint Prosthesis
Hydroxilapatite
The Wehrs II features a cut-out in the head of the prosthesis which adds increased strength and handling characteristics.
Catalog Number Description Dimensions
    A B C
7014-0982 0.9 mm, Short 5.3 mm 4.1 mm 2.5 mm
7014-0983 0.9 mm, Average 6.3 mm 5.2 mm 2.5 mm
7014-0984 0.9 mm, Medium 7.3 mm 6.1 mm 2.5 mm
7014-0985 0.9 mm, Large 10.2 mm 9.0 mm 2.5 mm
 
 
  Wood Incudostapedial Joint Prosthesis
Hydroxilapatite
Cat. Number Description Dimensions Functional Length
7014-0958 Partially Cannulated, 4 mm Diameter 4.6 x 3 x 1.5 mm 4 mm Trimmable
 
 
 
  Black Oval-Top PORPTM Prostheses
Oval top head is made of dense hydrolapatite and designed to minimize extrusion by eliminating any sharp edges. Easily trimmaable Plasti-PoreTM or fluoroplastic shafts are cannlated to acommodate the shapes capitulum.
Catalog Number Material Cannulated Head Diameter Overall Length
14-0859 Hydroxylapatite/ Plasti-PoreTM Partially, 1.5 mm 4 x 3 mm 6.6 mm
14-0857 Hydroxylapatite/Fluoroplastic Partially, 1.5 mm 4 x 3 mm 6.6 mm
As developed in conjunction with Bruce Black, M.D., Brisbane, Australia.
 
 
  Black Oval-Top Universal Prostheses
This modular approach to prosthesis design minimizes O.R. inventory by including both a PORPTM and TORPTM shaft which can be assembled in the prosthesis head. Shafts may be trimmed to length as necessary.
Catalog Number Description Cannulated PORP Type Shaft Diameter TORP Type Shaft Diameter
14-0861 4 x 3 mm Head Hydroxylapatite/ Plasti-PoreTM 1.15 mm 0.8 mm (wire)
14-0860 4 x 3 mm Head Hydroxylapatite/ Fluoroplastic 1.15 mm 0.8 mm
Requires O.R. assembly, only one shaft is actually used.
U.S. Patent Nos. 4,597,764; D286,909; D286,910.
As developed in conjuction with Bruce Black, M.D., Brisbane; Australia.
 
 
  CAP PORPTM Prosthesis
Cartilage attached prosthesis
Catalog Number Material Cannulated Dimensions Functional Length
14-0859 Hydroxylapatite Head/ HapexTM Shaft Partially, 1.7 mm 3.5 mm 9 mm
Developed in conjunction with David C. Kelsall, M.D., Denver, CO.
 
 
  Dornhoffer Malleable PORPTM Prosthesis
 
Catalog Number Material Cannulated Dimensions Functional Length
7014-5842 Hydroxylapatite Head/ Hapex Shaft Partially, 1 mm 4 x 3.2 mm 5 mm
Designed for John Dornhoffer, M.D., Little Rock, AR.
 
 
  Dornhoffer Malleable PORPTM Prosthesis
 
Catalog Number Material Head Diameter Functional Length with Cradle Overall Length
7014-1014 Hydroxylapatite Head/ Titanium Shaft 3.2 mm 2.0 mm 3 mm
Designed for John Dornhoffer, M.D., Little Rock, AR.
 
 
  Drum-to-Stapes Prosthesis PORPTM
Plasti-PoreTM
Hollow post of prosthesis seats firmly on stapes; the thin, broad-faced flange seats against the tympanum with carilage graft. Plasti-PoreTM material construction invites tissue ingrowth to quickly stabilize the prosthesis. Can be to fit, as desired.
Catalog Number Cannulated Flange Diameter Overall Length
14-0059 Partially, 1.17 mm 4 mm 4.75 mm
Designe for Ralph J. Carprosa, M.D., Pitsburg, PA.
 
 
  Drum-to-Stapes Prosthesis PORPTM
Plasti-PoreTM
Hollow post of prosthesis seats firmly on stapes; the thin, broad-faced flange seats against the tympanum with carilage graft. Plasti-PoreTM material construction invites tissue ingrowth to quickly stabilize the prosthesis. Can be to fit, as desired.
Catalog Number Cannulated Flange Diameter Overall Length
14-0059 Partially, 1.17 mm 4 mm 4.75 mm
Designe for Ralph J. Carprosa, M.D., Pitsburg, PA.
 
 
  Goldenberg Cap Prostheses
Hydroxilapatite
Dense hydroxylapatite cap sold separately, to be used in shallow middle ear spaces.
Catalog Number Cannulated Overall Length
14-0963 Fully 1.5 mm
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH.
 
 
  Goldenberg Malleable PORPTM Prosthesis
Hydroxylapatite/Plasti-PoreTM
Wedg-shaped, hydroxylapatite head is versatile and may be used if malleus is present but rotated anterioly. Malleable shaft allows proper angulation against the drum and can be easily trimmed to length.
Catalog Number Cannulated Overall Length
14-0964 Partially 5.1 mm
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH.
 
 
  Goldenberg Malleable PORPTM Prosthesis
Hydroxylapatite Head/HAPEXTM Shaft
Catalog Number Cannulated Head Dimensions Overall Length
7014-5964 Fully, 1.17 mm 4 x 3mm 5.6 mm
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH.
 
 
  Goldenberg PORPTM Prosthesis
Hydroxylapatite/Plasti-PoreTM
Wedge-shaped hydroxylapatite head conforms to tympanic membrane and is cannulated to visualize the stapes capitulum. Plasti-Pore shaft is trimmable and can be notched for stapedius tendon.
Catalog Number Cannulated Overall Length
14-0916 Fully, 1.14 mm 5.5 mm
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH.
 
 
  Goldenberg PORPTM Prosthesis
Hydroxylapatite Head/HAPEXTM Shaft
Catalog Number Cannulated Head Dimensions Functional Length
7014-5916 Fully, 1.17 mm 4 x 3 mm 4.75 mm
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH.
 
 
  Haberman PORPTM Prosthesis
Hydroxylapatite Head/HAPEXTM Shaft
Slim design enhances visualization. Notched shaft acommodates stapes cura. Head designed with groove to acommodate malleus.
Catalog Number Description Cannulated Functional Length
7014-5871 Notched for Stapes Cura Partially, 1 mm 2.7 mm
Desgined for Jack Kartush, M.D., Michigan Ear Institute.
 
 
  Modified PORPTM Prosthesis
Plasti-PoreTM
The modified partial ossicular replacement prosthesis (PORPTM) features a cannulation of the prothesis stem which offers the surgeon visibility of the superstructure of the stapes during the entire surgical procedure. Made of Plasti-PoreTM material, a porous high-density polyethylene which is well-tolerates in the body as an implant, the post of the prosthesis seats firmly on the stapes and replaces the malleus and the incus. The implant may be trimmed as desired.
Catalog Number Cannulated Flange Diameter Overall Length
14-0084 Fully, 1.17 mm 4 mm 5 mm
Designed for Leslie J. Block, M.D., Chicago, IL.
 
 
  MicronTM Adjustable Titanium PORPTM Prosthesis
Titanium
The MicronTM Titanium PORPTM features a large open-head design for good visualization. Its adjustable nature allows for minimal stocking levels.
Catalog Number Description Dimensions
7014-1046 Centered 2 - 5 mm
7014-1047 Off - Centered 2 - 5 mm
Catalog Number Description (May Be Used with Above Products)
7013-5802 Sizing Block
55-0108 Ryder Needle Holder (Implant Crimper)
 
 
  MicronTM All Titanium PORPTM
Titanium
The Monolithic PORPsTM come pre-sized so that the surgeon does not need to trim the prosthesis. Additionally, the open-head design allows for good visualization.
Catalog Number Description Functional Length Cradle Functional Diameter Head Diameter
7014-2036 Centered, Titable Head 1.5 mm 1 mm 3 mm
7014-2004 Centered, Titable Head 2 mm 1 mm 3 mm
7014-2028 Centered, Titable Head 2.5 mm 1 mm 3 mm
7014-2005 Centered, Titable Head 3 mm 1 mm 3 mm
7014-2029 Centered, Titable Head 3.5 mm 1 mm 3 mm
7014-2006 Centered, Titable Head 4 mm 1 mm 3 mm
7014-2007 Off - Centered, Titable Head 2 mm 1 mm 3 mm
7014-2030 Off - Centered, Titable Head 2.5 mm 1 mm 3 mm
7014-2008 Off - Centered, Titable Head 3 mm 1 mm 3 mm
7014-2031 Off - Centered, Titable Head 3.5 mm 1 mm 3 mm
7014-2009 Off - Centered, Titable Head 4 mm 1 mm 3 mm
 
 
  MicronTM Titanium PORPTM With Cradle
Titanium/Hapex
Tiltable titanium head and cradle with trimmable HapexTM shaft.
Catalog Number Description Functional Length Cradle Functional Diameter Head Diameter
7014-2002 Centered, Titable Head 4.8 mm 5.8 mm 3 mm
7014-2003 Off - Centered, Titable Head 4.8 mm 5.8 mm 3 mm
 
.
  Off-Centered Cap Prosthesis
Hydroxylapatite
An off-centered version of the Shea Cap Prosthesis, used when anatomy does not permit a direct reconstruction.
Catalog Number Cannulated Flange Diameter Overall Length
7014-5840 Partially, 1 mm 3 mm 1.5 mm
An developed in conjuction with John J. Shea, M.D., Memphis, TN.
 
 
  Off-Centered PORPTM Prosthesis
Plasti-Pore
The Off-Centered Plasti-Pore PORPTM is completely cannulated, allowing the surgeon visibility of the superstructure of the stapes during surgery. The position of the shaft permits a direct, rather than angled, stapes to tympanum placement. The implant is made of Plasti-PoreTM material, a porous, hight-density polyethylene which is well-tolerated in the body. The implant may be trimmed as desired.
Catalog Number Cannulated Flange Diameter Overall Length
14-0051 Fully, 1.17 mm 4 mm 4.57 mm
 
 
  Richards Centered Malleable PORPTM Prosthesis
Hydroxylapatite Head/HAPEXTM Shaft
Catalog Number Cannulated Flange Diameter Overall Length
7014-5889 Partially, 1.17 mm 3.5 mm 5.8 mm
 
 
  Richards Centered PORPTM Prosthesis
Hydroxylapatite
Fully Cannulated hydroxylapatite partial ossicular replacement prosthesis.
Catalog Number Cannulated Flange Diameter Overall Length
14-0892 Fully, 1.17 mm 4 mm 5.1 mm
 
 
  Richards Centered PORPTM Prosthesis
Hydroxylapatite Head/HAPEXTM Shaft
Catalog Number Cannulated Flange Diameter Overall Length
7014-5891 Partially, 1.17 mm 3.5 mm 5.9 mm
 
 
  Richards Off-Centered Malleable PORPTM Prosthesis
Hydroxylapatite Head/HAPEXTM Shaft
Catalog Number Cannulated Flange Diameter Overall Length
7014-5892 Partially, 1.17 mm 3.5 mm 5.8 mm
As developed in conjuction with Robert Goldenberg, M.D., Dayton, OH.
 
 
 
  Richards Off-Centered PORPTM Prosthesis
Hydroxilapatite
Catalog Number Cannulated Flange Diameter Overall Length
14-0893 Fully, 1.17 mm 4 mm 5.1 mm
 
 
  Richards Off-Centered PORPTM Prosthesis
Hydroxylapatite Head/HAPEXTM Shaft
Catalog Number Cannulated Flange Diameter Overall Length
7014-5893 Fully, 1.17 mm 3.5 mm 5.9 mm
 
 
  Schuring Ossicle Cup System
Hydroxylapatite/Fluoroplastic
Intended as a malleus-incus replacement, the Schuring Ossicle Cup System is designed with two parts, a fluoroplastic shaft and a hydroxylapatite cap. The easily trimmable fluoroplastic shaft is cupped to accommodate the stapes capitulum. The partially cannulated cap accommodates the shaft is designed to rest against the tympanic membrane. Each piece can be ordered separately or as set.
Catalog Number Name Description
14-1005 Ossile Cup System Head, 3.8 mm diameter, cannulated to size of shaft diameter (0.58 mm), one set per pack-age (1 each head and shaft)
14-1000 Ossile Cup Prosthesis Only Shaft, 6 mm long, 0.6 mm diameter; cup, 1.15 mm inside diameter, fluoroplastic material
14-1003 Hydroxilapatite Head Only 3.8 mm diameter, cannulated for Ossile Cup Prosthesis (0.58 mm)
As developed in conjunction with Arnold Schuring, M.D., Warren, OH.
 
 
  Shea Cap Prosthesis
Hydroxylapatite
This versatily prosthesis functions as a short PORPTM-type prosthesis, or can be used in conjunction with other available implants or materials to bridge ossicular defects.
Catalog Number Cannulated Base Diameter