Inicio Catálogos de JJP ¿Dónde puede localizarnos? Novedades   Buscador  
O.R.L.Prótesis de Oídos → Accesorios
Accesorios   Catálogo en PDF
 

 

  Attic Defect Plates
Porous Hydroxylapatite
Designed to be used in reconstructing defects in case of intact canal wall mastoidectomy. The semicircular implants are intended for use in sealing attic defects, and promoting complete obliberation of the site. They are offered in 3 sizes, to accommodate individual patient needs.
Catalog Number Description Diameter Thickness
14-0862 Small 7 mm 1 mm
14-0863 Description 10 mm 1 mm
14-0864 Large 14 mm 1 mm
As developed in conjunction with Bruce Black, M.D., Brisbane, Australia.
 
 
  Grote Canal Wall Prostheses
Porous Hydroxylapatite
The Grote Canal Wall Prosthesis is designed for the reconstrucion of the posterior bony ear canal wall. The prosthesis is available in three sizes to better fit individual patient needs. It can also be shaped using an appropiate diamond burr and irrigation.
Catalog Number Descfription Dimensions
A B C
14-0866 Small 13 mm 12 mm 16 mm
14-0867 Medium 14 mm 13 mm 18 mm
14-0868 Large 16 mm 15 mm 20 mm
Designed by Jan J. Grote, M.D., Leiden, The Netherlands.
 
 
  Porous Hydroxylapatite Reconstruction Blocks
Porous Hydroxylapatite
Porous hydroxylapatite implants for reconstruction of bony defects or argumentation of bony deficiencies. Made of highly bicompatible hydroxylapatite material, these blocks are useful in plastic surgery, and in oral and maxillofacial procedures where homograft and autograft bone is normally used. Pore Size Range: 150 to 350 microns. Porosity Range: 15 to 30%.
Catalog Number Description Dimensions
A B C
14-0871 Small Porous Block 5 mm 10 mm 30 mm
14-0872 Medium Porous Block 10 mm 10 mm 30 mm
14-0873 Large Porous Block 20 mm 20 mm 30 mm
 
 
  Williams Microclips
Stainless Steel
The Williams Microclip offers another method for holding the tympanic graft securely in position. The microclip offers the following advantages.
1.
Reduces the possibility of dislodging the positioned anterior graft segment.
2.
Allows the surgeon to fasten down the graft in stages, one area at a time.
3.
Assures the surgeon that the graft remains securely in position even when visibility is obscured during placement of packing material.
Sold three per sterile package.
Catalog Number Name Description I.D. Wire Diameter Units per Package
14-5285 Microclip   1.27 mm 0.13 mm 3
13-0830 Microclip Inserter Forceps, 1.27 mm Serrated Jaw 6 mm    
Designed for J. David Williams, M.D., Anchorage, Alaska.
 
 
 
Diseño: Estudios MIRE, SC   © 2008       JJP HOSPITALARIA, SL